Correlation to FVIII:C in Two Thrombin Generation Tests: TGA-CAT and INNOVANCE ETP
نویسندگان
چکیده
Introduction Several thrombin-generation tests are available, but few have been directly compared. Our primary aim was to investigate the correlation of two thrombin generation tests, thrombin generation assay-calibrated automated thrombogram (TGA-CAT) and INNOVANCE ETP, to factor VIII levels (FVIII:C) in a group of patients with hemophilia A. The secondary aim was to investigate inter-laboratory variation for the TGA-CAT method. Methods Blood samples were taken from 45 patients with mild, moderate and severe hemophilia A. The TGA-CAT method was performed at both centers while the INNOVANCE ETP was only performed at the Stockholm center. Correlation between parameters was evaluated using Spearman's rank correlation test. For determination of the TGA-CAT inter-laboratory variability, Bland-Altman plots were used. Results The correlation for the INNOVANCE ETP and TGA-CAT methods with FVIII:C in persons with hemophilia (PWH) was r=0.701 and r=0.734 respectively.The correlation between the two methods was r=0.546.When dividing the study material into disease severity groups (mild, moderate and severe) based on FVIII levels, both methods fail to discriminate between them.The variability of the TGA-CAT results performed at the two centers was reduced after normalization; before normalization, 29% of values showed less than ±10% difference while after normalization the number increased to 41%. Conclusions Both methods correlate in an equal manner to FVIII:C in PWH but show a poor correlation with each other. The level of agreement for the TGA-CAT method was poor though slightly improved after normalization of data. Further improvement of standardization of these methods is warranted.
منابع مشابه
Monitoring Low Molecular Weight Heparins at Therapeutic Levels: Dose-Responses of, and Correlations and Differences between aPTT, Anti-Factor Xa and Thrombin Generation Assays
BACKGROUND Low molecular weight heparins (LMWH's) are used to prevent and treat thrombosis. Tests for monitoring LMWH's include anti-factor Xa (anti-FXa), activated partial thromboplastin time (aPTT) and thrombin generation. Anti-FXa is the current gold standard despite LMWH's varying affinities for FXa and thrombin. AIM To examine the effects of two different LMWH's on the results of 4 diffe...
متن کاملThrombinbildung bei Kindern mit angeborenem Herzfehler - Bestimmung durch kalibrierte automatisierte Thrombographie
Thrombin generation was studied in paediatric patients with congenital heart disease (CHD) undergoing cardiac surgery using the calibrated automated thrombography (CAT) in terms of the lag time until the onset of thrombin formation, time to thrombin peak maximum (TTP), endogenous thrombin potential (ETP), and thrombin peak height. The suitability to determine the coagulation status of these pat...
متن کاملThrombin generation and rotational thromboelastometry in the healthy adult population.
AIM Published data on thrombin generation variables and their correlation with thromboelastometry in the healthy population are scarce. This study aimed at assessing thrombin generation in adults and its correlation to classical rotational thromboelastometry (ROTEM). METHODS Thrombin generation was measured in platelet-poor plasma from healthy volunteers using the calibrated automated thrombo...
متن کاملThrombin generation increasing with age and decreasing with use of heparin indicated by calibrated automated thrombogram conducted in Chinese.
OBJECTIVE Calibrated Automated Thrombogram(CAT) is a test to monitor the generation of thrombin. It can be described by four parameters: lag time, peak thrombin, endogenous thrombin potential (ETP) and time to peak (ttPeak). This study aims to determine the normal ranges of CAT parameters in Chinese, and evaluate whether thrombin generation is correlated with the concentration of heparin/low mo...
متن کاملCoagulation Proteins Influencing Global Coagulation Assays in Cirrhosis: Hypercoagulability in Cirrhosis Assessed by Thrombomodulin-Induced Thrombin Generation Assay
BACKGROUND Liver disease is accompanied by profound hemostatic disturbances. We investigated the influences of pro- and anticoagulation factors on global coagulation tests including prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin generation assay (TGA) in cirrhosis. We also investigated whether cirrhotic patients exhibit hypo- or hypercoagulability using the TG...
متن کامل