Falsely increased immunoassay measurements of total and unbound phenytoin in critically ill uremic patients receiving fosphenytoin.

نویسندگان

  • W L Roberts
  • B K De
  • J P Coleman
  • T M Annesley
چکیده

BACKGROUND Fosphenytoin, a phosphate ester prodrug of phenytoin, is metabolized to phenytoin in vivo. Phenytoin metabolites accumulate in renal insufficiency and cross-react in some phenytoin immunoassays. Our aim was to determine the accuracy of phenytoin immunoassays in renal patients treated with fosphenytoin. METHODS We measured phenytoin with HPLC and with the aca, ACS:180, TDx phenytoin II, Vitros, and AxSYM methods. Specimens were collected 2-120 h after fosphenytoin administration from 17 patients with renal insufficiency. RESULTS The AxSYM, TDx phenytoin II, ACS:180, and Vitros assays displayed falsely increased phenytoin results up to 20 times higher than the HPLC results. The aca Star results for these specimens were comparable to the HPLC results. Although fosphenytoin can cross-react with phenytoin immunoassays, no fosphenytoin was detected by a sensitive HPLC method in any sample that was tested for its presence. CONCLUSION These results are consistent with the formation of one or more novel metabolites or adducts of fosphenytoin that accumulate in some critically ill patients with renal insufficiency and that display significant cross-reactivity with some, but not all, phenytoin immunoassay methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glucuronidation of prodrug reactive site: isolation and characterization of oxymethylglucuronide metabolite of fosphenytoin.

BACKGROUND This investigation was undertaken to identify the structure of a novel immunoreactive metabolite derived from fosphenytoin that has been hypothesized previously as present in sera from renally impaired patients receiving this prodrug. METHODS The metabolite was isolated from uremic sera using solid-phase extraction and HPLC. Structural analysis was performed using HPLC-tandem mass ...

متن کامل

Total, Unbound Plasma and Salivary Phenytoin Levels in Critically Ill Patients

Objective: To assess the reliability of salivary phenytoin (PHT) concentrations and predicted free PHT levels by Sheiner-Tozer equation in order to substitute measured free PHT concentrations in critically ill patients. Methodology: Twenty-four neurocritically ill adult patients receiving intravenous PHT were included in the study. Analyses of total, free plasma and saliva PHT concentrations we...

متن کامل

Cross-reactivity of fosphenytoin in two human plasma phenytoin immunoassays.

The cross-reactivity of fosphenytoin, a phosphate ester prodrug of phenytoin, was investigated in the Abbott phenytoin TDx/TDxFLx fluorescence polarization immunoassay (TDx) and the Behring Diagnostics phenytoin Emit 2000 enzyme-multiplied immunoassay (Emit). The first part of our study investigating cross-reactivity utilized in vitro correlation of the two immunoassays with a validated and spe...

متن کامل

Phenytoin toxicity associated with hypoalbuminemia in critically ill patients.

Four critically ill patients developed phenytoin toxicity. Hypoalbuminemia or concomitant displacing drugs resulted in an increased fraction of unbound drug. Clinical findings included gradual decrease in level of consciousness and cerebellar signs. Marked phenytoin toxicity can occur in critically ill patients with hypoalbuminemia and can often be detected only by direct measurement of free ph...

متن کامل

Serum creatinine concentration and the discrepancy between enzyme multiplied immunoassay technique and gas-liquid chromatographic phenytoin levels.

In patients on phenytoin therapy and with renal failure, the enzyme multiplied immunoassay technique (EMIT), unlike gas-liquid chromatographic techniques (GLC), can give falsely elevated serum phenytoin concentrations. In 25 patients (creatinine less than or equal to 1.5 mg per dl), discrepancies between the serum EMIT and GLC phenytoin concentrations were accounted for by the inherent imprecis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 45 6 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1999