Virtual endobronchial ultrasound for transbronchial needle aspiration.
نویسندگان
چکیده
OBJECTIVE Endobronchial ultrasound-guided transbronchial needle aspiration could be performed better with computer-based preparation. METHODS Three-dimensional virtual bronchoscopy was used to develop 2 modes of computer-based "virtual endobronchial ultrasound." "Virtual endobronchial ultrasound standard" used conventional virtual bronchoscopy to determine the spot and angle for transbronchial needle aspiration, which was further evaluated by virtual bronchoscopy. "Virtual endobronchial ultrasound advanced" used multiple layers of 3-dimensional images of the target lesions and associated vascular structures in combination with virtual bronchoscopy. Target lesions and associated vascular structures (eg, pulmonary artery) were visualized through half-transparent bronchial walls. RESULTS Both methods required 5 to 15 minutes of preparation per case. Virtual endobronchial ultrasound standard required only basic computer software for virtual bronchoscopy, whereas virtual endobronchial ultrasound advanced required an advanced computer application. Virtual endobronchial ultrasound advanced allowed for a more intuitive recognition of the target. Both methods were useful in evaluating the feasibility of transbronchial needle aspiration, especially when the target was out of regular mediastinal lymph nodes, or in targeting a lesion located at a high upper angle (eg, 4L lymph node). Because the puncture spot was predetermined, bronchoscopists did not have to search for the target using ultrasound at the time of actual endobronchial ultrasound-guided transbronchial needle aspiration; rather, ultrasound was used only for confirmation of the target location and visualization of transbronchial needle aspiration. CONCLUSIONS Both computer-based preparation methods of virtual endobronchial ultrasound were useful in predetermining the puncture spot of transbronchial needle aspiration, suggesting their potential complementary role to the conventional technique of endobronchial ultrasound-guided transbronchial needle aspiration.
منابع مشابه
Endobronchial ultrasound–guided transbronchial needle aspiration in the staging of lung cancer patients
OBJECTIVE Mediastinoscopy as diagnostic procedure for evaluation of mediastinum in patients with non-small-cell lung cancer has long been considered the reference standard. However, less invasive method has occurred. Endobronchial ultrasound-guided transbronchial needle aspiration came into widespread use and has resulted in controversy as to whether it is a good replacement for mediastinoscopy...
متن کاملEndobronchial ultrasound-guided transbronchial needle aspiration of hilar and mediastinal lymph nodes detected on 18F-fluorodeoxyglucose positron emission tomography/computed tomography
OBJECTIVE Endobronchial ultrasound-guided transbronchial needle aspiration is of diagnostic value in hilar/mediastinal (N1/N2) lymph node staging. We assessed the utility of endobronchial ultrasound-guided transbronchial needle aspiration in lung cancer patients with N1/N2 lymph nodes detected on (18)F-fluorodeoxyglucose positron emission tomography/computed tomography. METHODS Fifty lung can...
متن کاملIntrapulmonary schwannoma diagnosed with endobronchial ultrasound-guided transbronchial needle aspiration: case report.
A 47-year-old woman was referred to our hospital for further examination of a lung tumor. CT of the chest revealed a round, well-defined 2.4-cm nodule in S2, adjacent to right superior lobe bronchus. Endobronchial ultrasonography showed a well-defined, hypoechoic tumor with echogenic capsule and posterior acoustic enhancement. Diagnosis of schwannoma was confirmed from the specimen obtained by ...
متن کاملEndobronchial mass formation after endobronchial ultrasound–transbronchial needle aspiration mimicking implantation metastasis
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has been widely used for diagnosing intrathoracic lymphadenopathy. Here, we present two cases of endobronchial polyp formation after an EBUS-TBNA for suspicious malignant lymph nodes. An inflammatory polyp should be considered as a possible differential diagnosis for a newly developed mass after an EBUS-TBNA.
متن کاملInfectious complications from full extension endobronchial ultrasound transbronchial needle aspiration.
The development of a convex probe endobronchial ultrasound (CP-EBUS) videobronchoscope to allow real-time transbronchial needle aspiration (TBNA) has been a significant advance in minimally invasive lung cancer staging and diagnosis. Several recent studies have demonstrated CP-EBUS-TBNA to have recovery rivalling that of the current gold standard, cervical mediastinoscopy. These same studies ha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of thoracic and cardiovascular surgery
دوره 146 5 شماره
صفحات -
تاریخ انتشار 2013