Validation of stationary phases in (111)In-pentetreotide planar chromatography.
نویسندگان
چکیده
INTRODUCTION Since Pall-German stopped manufacturing ITLC-SG, it has become necessary to validate alternative stationary phases. OBJECTIVE To validate different stationary phases versus ITLC-SG Pall-Gelman in the determination of the radiochemical purity (RCP) of (111)In-pentetreotide ((111)In-Octreoscan) by planar chromatography. MATERIAL AND METHODS We conducted a case-control study, which included 66 (111)In-pentetreotide preparations. We determined the RCP by planar chromatography, using a freshly prepared solution of 0,1M sodium citrate (pH 5) and the following stationary phases: ITLC-SG (Pall-Gelman) (reference method), iTLC-SG (Varian), HPTLC silica gel 60 (Merck), Whatman 1, Whatman 3MM and Whatman 17. For each of the methods, we calculated: PRQ, relative front values (RF) of the radiopharmaceutical and free (111)In, chromatographic development time, resolution between peaks. We compared the results obtained with the reference method. The statistical analysis was performed using the SPSS program. The p value was calculated for the study of statistical significance. RESULTS The highest resolution is obtained with HPTLC silica gel 60 (Merck). However, the chromatographic development time is too long (mean=33.62minutes). Greater resolution is obtained with iTLC-SG (Varian) than with the reference method, with lower chromatographic development time (mean=3.61minutes). Very low resolutions are obtained with Whatman paper, essentially with Whatman 1 and 3MM. Therefore, we do not recommend their use. CONCLUSIONS Although iTLC-SG (Varian) and HPTLC silica gel 60 (Merck) are suitable alternatives to ITLC-SG (Pall-Gelman) in determining the RCP of (111)In-pentetreotide, iTLC-SG (Varian) is the method of choice due to its lower chromatographic development time.
منابع مشابه
Review High-performance liquid chromatographic enantioseparation of drugs containing multiple chiral centers on chiral stationary phases
In recent years there has been considerable interest in the synthesis and separation of enantiomers of organic compounds especially because of their importance in the biochemistry and pharmaceutical industry. High-performance liquid Chromatography is a very useful method for the direct separation of enantiomers. However, about 30−40 years ago, commercially available chiral stationary phases wer...
متن کاملReconstruction parameters for 111In-pentetreotide SPECT: variability with respect to body weight and body region.
UNLABELLED This study, which was based on a large series of consecutive patients imaged by (111)In-pentetreotide SPECT for a neuroendocrine tumor, evaluated variability in reconstruction parameters in relation to patient body weight and the body region imaged, looking for the possibility of standardizing such parameters. METHODS One hundred twenty-four patients underwent (111)In-pentetreotide...
متن کاملNovel Atom-Type-Based Topological Descriptors for Simultaneous Prediction of Gas Chromatographic Retention Indices of Saturated Alcohols on Different Stationary Phases
In this work, novel atom-type-based topological indices, named AT indices, were presented as descriptors to encode structural information of a molecule at the atomic level. The descriptors were successfully used for simultaneous quantitative structure-retention relationship (QSRR) modeling of saturated alcohols on different stationary phases (SE-30, OV-3, OV-7, OV-11, OV-17 and OV-25). At first...
متن کاملShape-selective separation of polycyclic aromatic hydrocarbons by reversed-phase liquid chromatography on tetraphenylporphyrin-based stationary phases.
The reversed-phase chromatographic behavior of planar and non-planar polycyclic aromatic hydrocarbons (PAHs) is investigated on tetraphenylporphyrin and two metallotetraphenylporphyrin [Sn(IV), In(III)] bonded stationary phases using methanol-water and acetonitrile-water as mixed solvent mobile phases. Large differences in the capacity factors of aromatic solute pairs having the same number of ...
متن کاملSarcoidosis mimicking metastatic carinoid on indium-111 pentetreotide scintigraphy
Carcinoid is a neuroendocrine neoplasm derived from primitive stem cells, occurring most frequently in the alimentary tract. Somatostatin-receptor scintigraphy with indium-111 pentetreotide is a sensitive and noninvasive technique for imaging carcinoid and its metastatic spread. However, nontumoral lesions such as sarcoidosis may also express somatostatin receptors, which may present a diagnost...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de medicina nuclear e imagen molecular
دوره 32 5 شماره
صفحات -
تاریخ انتشار 2013