Dose Calculation Accuracy and Algorithm Validation of Low Density Heterogeneities in Co

ثبت نشده
چکیده

Telecobalt machine is one of the essential equipment needed in many cancer centers and still prominently used for the treatment of a variety of cancer cases in developing countries. This study aims to evaluate the impact of tissue heterogeneity corrections on 3D treatment planning system (Prowess). The human body contains a variety of tissues and cavities which vary widely in their physical and radiological properties. The presence of these heterogeneities in the path of telecobalt beam causes an altered dose distribution in the region of clinical interests. A computerized treatment planning system (TPS) is generally used for calculating the dose distribution in the patient. Experimental measurements were carried out in a telecobalt beam with the objectives to study the effects of low-density heterogeneities and to verify the ability of the Prowess radiotherapy TPS in predicting the altered dose distribution along the central axis and off-axis of the beam. All measurements were carried out in a PTW RW3 solid slab phantom by introducing heterogeneous waterlung equivalent phantom (full slab and lung geometry). A comparison of experimentally measured and TPS calculated dose values indicate that the TPS overestimates the dose by 12.7% in lung equivalent (Cork) heterogeneity along the central axis. For air heterogeneity of 1.0 and 2.0cm, a comparison of experimentally measured and TPS calculated dose values indicate that the TPS overestimates the dose by 3.9% and 5.9%, respectively. While testing the adequacy of TPS in off-axis region, it was found that the TPS calculation does not indicate the widening of the beam profile in the lowdensity heterogeneity region. This study suggests that the Prowess algorithm TPS is unable to achieve the recommended 3% accuracy of clinical dose calculation in heterogeneous media and air gap.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Dose calculation algorithms of Monaco Treatment Planning System in the heterogeneities area

Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...

متن کامل

Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements

Aims: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2.Materials and Methods: Authors employed kailwood (Pinus Wallichiana) to mimic lung. Briefly, seven Kailwood plates, each measuring 25x...

متن کامل

Evaluation of the accuracy of calculated dose with the EPL and ETAR algorithms using thorax CIRS phantom.

Introduction: Each treatment planning algorithm has some errors in dose calculation. Particularly these errors are more pronounced in the heterogeneous regions. It is recommended for each set of radiation data and algorithm subtle deliberation done regarding dose calculation accuracy. Knowing the amount of error in dose calculation will result in a fairly accurate estimate of t...

متن کامل

Evaluation of Dose Calculation Algorithms Accuracy for Eclipse, PCRT3D, and Monaco Treatment Planning Systems Using IAEA TPS commissioning tests in a Heterogeneous Phantom

Introduction: The accuracy of dose calculation algorithm (DCA) is highly considered in the radiotherapy sequences. This study aims at assessing the accuracy of five dose calculation algorithms in tissue inhomogeneity corrections, based on the International Atomic Energy Agency TEC-DOC 1583. Material and Methods: A heterogeneous phantom was sc...

متن کامل

Calculation of absorbed dose in lung tissue equivalent and compared it with prediction of a treatment planning system using Collapsed Cone Convolution algorithm

External radiotherapy is used for treatment of various types of cancers. Due to the impossibility of measuring the absorbed dose delivered to different organs during irradiation, treatment planning systems (TPSs) have been utilized for calculation of absorbed dose before a radiotherapy procedure. Thus, the accuracy and precession of the TPS is essential.The aim of this study is investigation of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013