Reliability of Isometric Knee Extension Muscle Strength Measurements of Healthy Elderly Subjects Made with a Hand-held Dynamometer and a Belt

نویسندگان

  • Munenori Katoh
  • Koji Isozaki
چکیده

[Purpose] The purpose of this study was to examine the reliability of three isometric knee extension strength measurements (IKE) made with a hand-held dynamometer (HHD) and a belt of healthy elderly living in the community as subjects. [Subjects] The subject cohort consisted of 186 healthy elderly people, aged 65 to 79 years, living in local communities. [Methods] IKE of the leg subjects used to kick a ball was measured. IKE of each subject was measured three times using an HHD-belt at intervals of 30 seconds. The reliability of the larger of the first two measurements (LV2) as well as the third measurement (3V) was investigated. [Results] The intraclass correlation coefficients [ICC (1, 1)] for LV2 and 3V were 0.955. Bland-Altman analysis showed a fixed bias, and the limits of agreement ranged from -5.6 to 4.6. [Conclusion] The ICC results show that the test-retest reproducibility of IKE measurements of healthy elderly subjects using an HHD-belt is high. However, Bland-Altman analysis showed a fixed bias, suggesting the need for three measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of isometric knee extension muscle strength measurements made by a hand-held dynamometer and a belt: a comparison of two types of device

[Purpose] The purpose of the present study was to compare the reliability of 2 hand-held dynamometers (HHD-1, 2) with different designs, by performing isometric knee muscle extension measurements two times each. [Subjects] The subjects were 40 young healthy adults. [Methods] The reliability of the measurements was examined using Bland-Altman analysis. [Results] Bland-Altman analysis found a fix...

متن کامل

Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults

[Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric k...

متن کامل

The Relationship Between Muscle Strength and Range of Motion in Lower Extremity, and Balance and Risk of Falling in the Elderly

Background: The present study examined the relationship between muscle strength and range of motion in the lower extremity, and balance and risk of falling in the elderly. Methods: This cross-sectional study was conducted on healthy elderly (mean±SD age: 65.64±4.95 y) in Rasht City, Iran. The study participants were 65 healthy male elderly who met the stud inclusion criteria. They were selecte...

متن کامل

An Investigation into Reliability of Knee Extension Muscle Strength Measurements, and into the Relationship between Muscle Strength and Means of Independent Mobility in the Ward: Examinations of Patients Who Underwent Femoral Neck Fracture Surgery

[Purpose] The purpose of the present study was to investigate the reliability of isometric knee extension muscle strength measurement of patients who underwent femoral neck fracture surgery, as well as the relationship between independent mobility in the ward and knee muscle strength. [Subjects] The subjects were 75 patients who underwent femoral neck fracture surgery. [Methods] We used a hand-...

متن کامل

Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt

[Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2014