The values shown on optical technology-based patient monitors must be cautiously interpreted: intravenous dye-induced errors
نویسنده
چکیده
dyes such as indocyanine green (ICG), indigo carmine, and methylene blue are commonly used during various surgical procedures. The intraoperative administration of intravenous dyes can result in misreadings of the actual values measured by optical technology-based patient monitors (i.e., cerebral oximeters and pulse oximeters) because they interfere with the amount of the specific infrared or red wavelength detected by each device. Therefore, clinicians would benefit from a narrow review of the effects of intravenously administered dyes on regional cerebral tissue oxygen saturation and percutaneous oxygen saturation readings. The pulse oximeter was developed based on the fact that oxygenated and reduced hemoglobin have different rates of absorption of red and infrared light (Lambert-Beer law). Oxyhe-moglobin absorbs more infrared light (990 nm), whereas deoxy-hemoglobin absorbs more red light (660 nm). The device detects the difference in the extent of absorption of two wavelengths of light (660 and 925 nm) in arterial blood. The value is automatically calculated as an absorption ratio (extent of light detected at 660 nm/extent of light detected at 925 nm) and is represented as the arterial oxygen saturation (SaO 2). Similar to pulse oximetry, cerebral near-infrared spectrometry measures the absorption ratio of two different wavelengths of near-infrared light (730 and 805 nm) in venous, capillary, and arterial blood and represents the value as the regional cerebral tissue oxygen saturation (SctO 2). In clinical practice, intraoperative ICG is commonly used during neurosurgery to confirm the patency of the anastomosed vessels after middle cerebral artery-superficial temporal artery bypass surgery or carotid endarterectomy and the completeness of the secured aneurysm after cerebral aneurysmal clipping. The peak absorption wavelength of ICG is 805 nm [1]. A clinical study published in this issue of the Korean Journal of Anesthesiology demonstrates that the intravenous injection of ICG can produce false increases in SctO 2 readings in a dose-dependent fashion [2]. This finding can be partly explained by an increase in the absorption ratio of two different wavelengths of light: 730 and 805 nm. In other words, ICG absorbs light with a wavelength of 805 nm, falsely decreasing the amount of 805 nm light detected by the cerebral oximeter; this light is displaced as an increased SctO 2 reading. Another recent study showed that intravenous ICG administration caused a false decrease in SaO 2 readings [2,3]. ICG acts similarly to deoxyhemoglobin in arterial blood; this falsely decreases the absorption ratio of red and infrared wavelengths …
منابع مشابه
Intravenous Tramadol-Induced Seizure: Two Case Reports
There are a few reports of seizure induced by tramadol at therapeutic dose. Two case reports of repeated seizures with following agitation due to treatment with tramadol are presented here. Both of them have similar presentation and tramadol was injected intravenously at therapeutic doses. Tramadol prescription especially intravenously can evoke seizure with agitation or even status epilepticus...
متن کاملThe Effect of Modern Educational Strategies in Reducing Intravenous Drug Administration Error: A Non-Randomized Clinical Trial
Introduction: Among medication errors, intravenous medication administration errors are especially important. The lack of medication information can be one of the causes of medication errors. Using electronic education may facilitate quick access to the update resources. The objective of this study is the evaluation of an appropriate educational strategy to reduce intravenous drug administratio...
متن کاملSynthesis and Characterization of Indoline-based organic sensitizers for photoelectrochemical cells
In this paper we designed and prepared three free-metal organic days Dye 1, Dye 2 and Dye 3 based on indoline with n-phenly substituents iminodibenzyl as the electron donor group. We used cyanoacrylic acid substituent as the electron acceptor anchoring group in organic dyes. The proposed dyes were prepared from iminodibenzyl as the starting material by standard reactions and characterized by di...
متن کاملN-Acetylcysteine Overdose After Acetaminophen Poisoning
N-acetylcysteine (NAC) is a drug used widely and effectively in oral and intravenous forms as a specific antidote for acetaminophen poisoning. In children considering the toxic dose of acetaminophen ingested by the patient and the body weight, the physician prescribes a specific dose of NAC. There is always a risk of iatrogenic overdose of NAC which can cause different mild to...
متن کاملN-Acetylcysteine Overdose After Acetaminophen Poisoning
N-acetylcysteine (NAC) is a drug used widely and effectively in oral and intravenous forms as a specific antidote for acetaminophen poisoning. In children considering the toxic dose of acetaminophen ingested by the patient and the body weight, the physician prescribes a specific dose of NAC. There is always a risk of iatrogenic overdose of NAC which can cause different mild to...
متن کامل