Passive vibration suppression using inerters for a multi-storey building structure

نویسندگان

  • Huixing Liu
  • Benmou Zhou
  • Zongkai Liu
  • Sara Ying Zhang
  • Jason Zheng Jiang
  • Simon Neild
چکیده

This paper investigates the use of inerters for vibration suppression of a multistorey building structure. The inerter was proposed as a two-terminal replacement for the mass element, with the property that the applied force is proportional to the relative acceleration across its terminals. It completes the force-current mechanical-electrical network analogy, providing the mechanical equivalent to a capacitor. Thus allows all passive mechanical impedances to be synthesised. The inerter has been used in Formula 1 racing cars and applications to various systems such as vehicle suspension have been identified. Several devices that incoporate inerter(s), as well as spring(s) and damper(s), have also been identified for vibration suppression of building structures. These include the tuned inerter damper (TID) and the tuned viscous mass damper (TVMD). In this paper, a three-storey building model with an absorber located at the bottom subjected to base excitation is studied. Four simple absorber layouts, in terms of how spring, damper and inerter components should be arranged, have been studied. In order to minimise the maximum relative displacement of the building, the optimum parameter values for each of the layouts have been obtained with respect to the inerter’s size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced computational design of shared tuned mass-inerter dampers for vibration control of adjacent multi-story structures ⋆

Inerters are a novel type of mechanical actuation devices that are able to produce large inertial forces with a relatively small mass. Due to this property, inerters can provide an effective solution to the main drawbacks of tuned mass-dampers and, consequently, they are gaining an increasing relevance in the field of passive structural vibration control. In this paper, a computational design s...

متن کامل

Passive vibration control: a structure-immittance approach.

Linear passive vibration absorbers, such as tuned mass dampers, often contain springs, dampers and masses, although recently there has been a growing trend to employ or supplement the mass elements with inerters. When considering possible configurations with these elements broadly, two approaches are normally used: one structure-based and one immittance-based. Both approaches have their advanta...

متن کامل

Semi-Active Pulse-Switching SSDC Vibration Suppression using Magnetostrictive Materials

One of the best vibration control methods using smart actuators are semi-active approaches which are as strong as active methods and need no external energy supply such as passive ones. Compared with piezoelectric-based, magnetostrictive-based control methods have higher coupling efficiency, higher Curie temperature, higher flexibility to be integrated with curved structures and no depolarizati...

متن کامل

A new method for drawing the capacity spectrum for seismic analysis and structural rehabilitation

A review of previous studies shows that there are two general views on how to determine demand in structures through incremental nonlinear static analysis. In the first view, multi-modal methods are used to determine demand in structures. In this view, the applied load pattern is applied to the structure according to the shape of each vibration mode, assuming that the structure deformation foll...

متن کامل

Assessment of Structure-Specific Fragility Curves for Soft Storey Buildings Implementing IDA and SPO Approaches

Soft storey building is popular due to the functional and aesthetic purpose, despite its weakness in resisting seismic excitation. Nonlinear Static (Pushover) Analysis (POA) is a time saving and simple assessment procedure prosposed in Eurocode 8 (EC8). However, its reliability in designing structure still remains a question. At the first stage, seismic performance of several building models us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017