Posterior rat eye during acute intraocular pressure elevation studied using polarization sensitive optical coherence tomography

نویسندگان

  • Stanislava Fialová
  • Marco Augustin
  • Corinna Fischak
  • Leopold Schmetterer
  • Stephan Handschuh
  • Martin Glösmann
  • Michael Pircher
  • Christoph K. Hitzenberger
  • Bernhard Baumann
چکیده

Polarization sensitive optical coherence tomography (PS-OCT) operating at 840 nm with axial resolution of 3.8 µm in tissue was used for investigating the posterior rat eye during an acute intraocular pressure (IOP) increase experiment. IOP was elevated in the eyes of anesthetized Sprague Dawley rats by cannulation of the anterior chamber. Three dimensional PS-OCT data sets were acquired at IOP levels between 14 mmHg and 105 mmHg. Maps of scleral birefringence, retinal nerve fiber layer (RNFL) retardation and relative RNFL/retina reflectivity were generated in the peripapillary area and quantitatively analyzed. All investigated parameters showed a substantial correlation with IOP. In the low IOP range of 14-45 mmHg only scleral birefringence showed statistically significant correlation. The polarization changes observed in the PS-OCT imaging study presented in this work suggest that birefringence of the sclera may be a promising IOP-related parameter to investigate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of the progression of retinal nerve fiber layer loss by optical coherence tomography in a patient with glaucomatocyclitic crisis

A 30-year-old man presented with glaucomatocyclitic crisis, also known as Posner-Schlossman syndrome, and acute intraocular pressure elevation. Changes in the longitudinal retinal nerve fiber layer (RNFL) and the cup-to-disc (C/D) ratio of the optic disc were detected by Stratus optical coherence tomography (OCT). The average RNFL thickness in the affected eye was greater than that in the unaff...

متن کامل

Deformation of the rodent optic nerve head and peripapillary structures during acute intraocular pressure elevation.

PURPOSE. To evaluate the effect of acutely elevated intraocular pressure (IOP) on retinal thickness and optic nerve head (ONH) structure in the rat eye by spectral domain-optical coherence tomography (SD-OCT). METHODS. Fourteen adult male Brown-Norway rats were studied under anesthesia (ketamine/xylazine/acepromazine, 55:5:1 mg/kg intramuscularly). Both eyes were imaged by SD-OCT on two baselin...

متن کامل

Short-Term Moderately Elevated Intraocular Pressure Is Associated With Elevated Scotopic Electroretinogram Responses

PURPOSE Moderately elevated intraocular pressure (IOP) is a risk factor for open-angle glaucoma. Some patients suffer glaucoma despite clinically measured normal IOPs. Fluctuations in IOP may have a significant role since IOPs are higher during sleep and inversion activities. Controlled transient elevations of IOPs in rats over time lead to optic nerve structural changes that are similar to the...

متن کامل

In vivo assessment of changes in corneal hysteresis and lamina cribrosa position during acute intraocular pressure elevation in eyes with markedly asymmetrical glaucoma

Purpose To investigate the biomechanical response of the cornea, lamina cribrosa (LC), and prelaminar tissue (PT) to an acute intraocular pressure (IOP) increase in patients with markedly asymmetrical glaucoma and in healthy controls. Patients and methods A total of 24 eyes of 12 patients with markedly asymmetrical primary open-angle glaucoma (POAG) and 12 eyes of 12 healthy patients were exa...

متن کامل

Lamina cribrosa measurements for glaucomatous eyes: a new focus point in optical coherence tomography

Submit Manuscript | http://medcraveonline.com network of collagen fibers. It has been considered that LC maintains the pressure gradient between intraocular pressure (IOP) and the periocular pressure and it structurally supports RGC axons. As LC is structurally weaker than other parts of sclera which are thicker and denser, it is highly sensitive to the effects of the IOP elevation.1,2 LC is a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017