Prevention of posterior capsule opacification by an intracapsular open capsule device.
نویسندگان
چکیده
PURPOSE To investigate the ability of an open capsule device to prevent posterior capsule opacification. METHODS A total of 40 eyes of 20 New Zealand white rabbits were randomly divided into six similar groups of 6 to 7 eyes each. After crystalline lens evacuation, one control group (group A) was implanted with a hydrophilic acrylic intraocular lens and no device, and another control group (group B) was implanted with a hydrophobic acrylic intraocular lens and no device. The study groups were implanted with a hydrophilic acrylic intraocular lens and a hydrophilic acrylic device (group C), a hydrophobic acrylic intraocular lens and a hydrophilic acrylic device (group D), a hydrophilic acrylic intraocular lens and a hydrophobic acrylic device (group E), and a hydrophobic acrylic intraocular lens and a hydrophobic acrylic device (group F). The rabbits were monitored for the ensuing 6 weeks and then killed. The enucleated eyes were evaluated using the Miyake-Apple view, Matlab software analysis, and histology. RESULTS The posterior capsule opacification score was significantly reduced in the eyes that were implanted with the tested device compared with the control eyes (clinical evaluation: 69% reduction, P = 0.001; the Miyake-Apple view analysis: 77% reduction, P = 0.000; histology: 75% reduction, P = 0.000). Soemmering's ring area was significantly reduced in the eyes implanted with the tested device compared with the control eyes (Matlab analysis: 80% reduction, P = 0.000). CONCLUSIONS The tested devices were effective in reducing posterior capsule opacification and Soemmering's ring formation.
منابع مشابه
A new endocapsular open ring for prevention of anterior and posterior capsule opacification
PURPOSE The aim of this study is to demonstrate the functionality of a new design of a thick endocapsular open ring for prevention of anterior capsule opacification (ACO) and posterior capsule opacification (PCO). SETTING The Institute of Vision and Optics, University of Crete and University Hospital of Heraklion, Crete, Greece. DESIGN Prospective, interventional pilot study. METHODS Fift...
متن کاملFurther Enhancement of Intraocular Open-Capsule Devices for Prevention of Posterior Capsule Opacification
Purpose We improve the intraocular open-capsule devices (IOCD) for the prevention of posterior capsule opacification (PCO). Methods A total of 45 New Zealand rabbit eyes were divided into six similar groups after crystalline lens evacuation. Each group was implanted with a hydrophilic intraocular lens (IOL) and a hydrophilic IOCD of different designs. In the first experiment (Part A), a squar...
متن کاملRisk factors for posterior capsule opacification.
I mprovements in techniques, instrumentation, and intraocular lens design appear to have been associated with declining rates of posterior capsule opacification following cataract surgery. While morbidity associated with posterior capsule opacification and its treatment, Nd:YAG laser capsulotomy, is limited, progressive opacification affects quality of vision and visual function, while capsulot...
متن کاملThe effects of three-piece or single-piece acrylic intraocular lens (IOL) implantation on posterior capsule opacification.
PURPOSE To evaluate the development of posterior capsule opacification (PCO) in patients implanted with 5.5 mm optics, single-piece or three-piece acrylic intraocular lens (IOL) in cataract surgery prospectively. METHODS This study was carried out on 267 eyes of 249 patients implanted with three-piece, 5.5 mm optics, acrylic IOL and 252 eyes of 244 patients implanted with single-piece, 5.5 mm...
متن کاملEpidemiological evaluation of YAG capsulotomy incidence for posterior capsule opacification in various intraocular lenses in Japanese eyes
BACKGROUND AND OBJECTIVE We investigated the yttrium aluminum garnet (YAG) capsulotomy rates in various intraocular lenses (IOLs). STUDY DESIGN/PATIENTS AND METHODS We retrospectively analyzed 23,440 eyes implanted with either MA60BM, MA60AC, VA-60BB, CeeOnEdge, Clariflex, Technis Z9002, SI-40NB, or UV26T IOLs. We calculated the YAG capsulotomy rates at 1, 3, 5, and 10 years post lens implant...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 55 7 شماره
صفحات -
تاریخ انتشار 2014