A Technique and Results Using a Specially Designed Knife

نویسندگان

  • K. I. Ha
  • M. J. Park
  • C. W. Ha
چکیده

We describe a safe and easy percutaneous technique for release of trigger finger using a specially designed knife. The A1 pulley is sectioned by a blade which has a hooked end. We released, percutaneously, 185 trigger fingers, including 62 which were locked using this technique. Satisfactory results were achieved in 173 (93.5%). There were no significant complications. We recommend this as a safe and effective outpatient procedure for those patients who have not responded successfully to conservative treatment, have longstanding symptoms or severe triggering.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gamma Knife Simulation Using the MCNP4C Code and the Zubal Phantom and Comparison with Experimental Data

Introduction: Gamma Knife is an instrument specially designed for treating brain disorders. In Gamma Knife, there are 201 narrow beams of cobalt-60 sources that intersect at an isocenter point to treat brain tumors. The tumor is placed at the isocenter and is treated by the emitted gamma rays. Therefore, there is a high dose at this point and a low dose is delivered to the normal tissue surroun...

متن کامل

Evaluation of Organ Specific peripheral dose for Gamma knife 4C based on Monte Carlo

Introduction: Stereotactic Gamma Knife radiosurgery has been widely used for treating brain tumors. The scattered radiation outside of treatment field (peripheral dose) can induce the secondary cancer to specific organ. This paper investigated the absorbed dose to eyes, thyroid, heart, lung, breast and colon using a Monte Carlo technique for Mird phantom. We also study the ef...

متن کامل

The percutaneous trigger finger release scalpel - the A knife

Open A1 pulley release is a standard surgical procedure for treatment of trigger finger. The disadvantages of the open technique include injury to the soft tissue, developing a painful palmar scar and patients requiring an extended recovery timethesince the procedure is more complex. Another technique used for treatment of trigger finger is percutaneous release. This technique offers the benefi...

متن کامل

Study the effect of source to diaphragm distance (SDD) on beam penumbra width of Gamma Knife machine model 4C using Monte Carlo simulation

Introduction: Stereotactic radiosurgery (SRS) is one of the conformal radiotherapy methods and Gamma Knife is a non-invasive SRS technique to treat intracranial lesions with 201 Co- 60 sources without need to surgery and bleeding. Beam penumbra phenomenon leads to irradiation outside the field and normal tissues. Therefore, considering it is momentous to attain the acceptable t...

متن کامل

Intracanal placement of calcium hydroxide: a comparison of specially designed paste carrier technique with other techniques

BACKGROUND This study compared the effectiveness of a Specially Designed Paste Carrier technique with the Syringe-Spreader technique and the Syringe-Lentulo spiral technique in the intracanal placement of calcium hydroxide. METHODS Three groups, each containing 15 single-rooted human anterior teeth were prepared using standardized Mtwo rotary instruments to a master apical file size 40 with 0...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004