Estimation of Depth Dose Curves with Sparse Non-equally Spaced Measurements Estimation of Depth Dose Curves with Sparse Non-equally Spaced Measurements

نویسنده

  • M. Juntunen
چکیده

The inverse problem formulation of the depth dose curve estimation is applied to sparse non-equally spaced measurement grid and the subsequent solution as well as the selection of measurement depths are discussed. The performance of the proposed estimation method is evaluated with real 6 MeV and 18 MeV photon data. These studies show that the proposed method allows the estimation of the depth dose curve typically from 12-14 observations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of wedged dose distributions using an analytical method

Introduction: Wedge filters are used in radiotherapy to modify photon beam and improve dose uniformity in the target volume. Determination of wedge dose distribution is important to improve treatment planning accuracy. The utilization of treatment planning software to obtain dose distribution is not always available. In this work an analytical model has been developed to calcu...

متن کامل

Benchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement

Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator.   Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...

متن کامل

Investigation of the Field Size Effect on Wedge Field Isodose Curves Angle for Two Energies; 6 & 18 MV, produced by VARIAN 2100C Linac

Introduction: Nowadays,  considerable developments  in  the field  of  radiotherapy have  been  achieved.  They  include  the  advances  made  in  the  equipments  and  treatment  planning  techniques  which  require  highly complex calculations. Such achievements have made it possible to treat cancer patients not only  with  higher  radiation  dose  but  also  with  higher  precision  and  con...

متن کامل

Total skin electron therapy (TSET): Monte Carlo Simulation and implementation

Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...

متن کامل

Functional Data Analysis for Sparse Longitudinal Data Short title: FDA for Sparse Longitudinal Data

We propose a nonparametric method to perform functional principal components analysis for the case of sparse longitudinal data. The method aims at irregularly spaced longitudinal data, where the number of repeated measurements available per subject is small. In contrast, classical functional data analysis requires a large number of regularly spaced measurements per subject. We assume that the r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998