Quantitative evaluation of aortic insufficiency by continuous wave Doppler echocardiography.

نویسندگان

  • A J Labovitz
  • R P Ferrara
  • M J Kern
  • R J Bryg
  • D G Mrosek
  • G A Williams
چکیده

To assess the usefulness of continuous wave Doppler echocardiography in the evaluation of aortic insufficiency, the aortic regurgitant flow velocity pattern obtained with continuous wave Doppler examination was compared with the results of aortography and conventional pulsed Doppler techniques in 25 individuals with aortic insufficiency. The diastolic deceleration slope as measured from the continuous wave tracing was significantly different among subgroups of patients with mild (1.6 +/- 0.5 m/s2), moderate (2.7 +/- 0.5 m/s2) and severe (4.7 +/- 1.5 m/s2) aortic insufficiency as determined from aortography. Deceleration slopes greater than 2 m/s2 separated individuals with moderate and severe insufficiency from those with mild insufficiency. Similar findings were seen when comparing the pressure half-time method of diastolic velocity decay with the more severe grades of aortic insufficiency exhibiting the shortest pressure half-times. There was also a high correlation (r = 0.85) between the deceleration slope measured by continuous wave Doppler recordings and the grade of insufficiency as assessed by pulsed Doppler echocardiography. End-diastolic velocities correlated poorly (r = 0.28) with catheter-measured end-diastolic pressure difference between the aorta and the left ventricle. These findings demonstrate that the aortic regurgitant flow pattern by continuous wave Doppler echocardiography may be useful in quantitating the degree of aortic insufficiency by assessing the rate with which aortic and left ventricular pressures equilibrate during diastole.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

Noninvasive evaluation of aortic regurgitation by continuous-wave Doppler echocardiography.

Continuous-wave Doppler echocardiography was used to examine the aortic regurgitant flow velocity pattern in 32 patients with aortic regurgitation (AR) and 10 patients without AR. The aortic regurgitant flow velocity patterns, characterized by a rapid rise in flow velocity immediately after closure of the aortic valve, high peak flow velocity, and a gradual deceleration until the next aortic va...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...

متن کامل

Quantitative assessment of the hemodynamic consequences of aortic regurgitation by means of continuous wave Doppler recordings.

The purpose of this study was to evaluate the ability of continuous wave Doppler ultrasound recordings to reflect the magnitude and hemodynamic effects of aortic regurgitation. Forty-five patients with angiographically proved aortic regurgitation had Doppler studies performed within 24 hours of cardiac catheterization. High quality spectral recordings of the regurgitant jet were obtained in 31 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 8 6  شماره 

صفحات  -

تاریخ انتشار 1986