A method for achieving an order-of-magnitude increase in the temporal resolution of a standard CRT computer monitor.
نویسندگان
چکیده
As the frequency of a flickering light is increased, the perception of flicker is replaced by the perception of steady light at what is known as the critical flicker fusion threshold (CFFT). This threshold provides a useful measure of the brain's information processing speed, and has been used in medicine for over a century both for diagnostic and drug efficacy studies. However, the hardware for presenting the stimulus has not advanced to take advantage of computers, largely because the refresh rates of typical monitors are too slow to provide fine-grained changes in the alternation rate of a visual stimulus. For example, a cathode ray tube (CRT) computer monitor running at 100Hz will render a new frame every 10 ms, thus restricting the period of a flickering stimulus to multiples of 20 ms. These multiples provide a temporal resolution far too low to make precise threshold measurements, since typical CFFT values are in the neighborhood of 35 ms. We describe here a simple and novel technique to enable alternating images at several closely-spaced periods on a standard monitor. The key to our technique is to programmatically control the video card to dynamically reset the refresh rate of the monitor. Different refresh rates allow slightly different frame durations; this can be leveraged to vastly increase the resolution of stimulus presentation times. This simple technique opens new inroads for experiments on computers that require more finely-spaced temporal resolution than a monitor at a single, fixed refresh rate can allow.
منابع مشابه
An Improvement in Temporal Resolution of Seismic Data Using Logarithmic Time-frequency Transform Method
The improvement in the temporal resolution of seismic data is a critical issue in hydrocarbon exploration. It is important for obtaining more detailed structural and stratigraphic information. Many methods have been introduced to improve the vertical resolution of reflection seismic data. Each method has advantages and disadvantages which are due to the assumptions and theories governing their ...
متن کاملPseudo Zernike Moment-based Multi-frame Super Resolution
The goal of multi-frame Super Resolution (SR) is to fuse multiple Low Resolution (LR) images to produce one High Resolution (HR) image. The major challenge of classic SR approaches is accurate motion estimation between the frames. To handle this challenge, fuzzy motion estimation method has been proposed that replaces value of each pixel using the weighted averaging all its neighboring pixels i...
متن کاملAssessment of Computer Regulation Thermography (CRT) as a Complemetrary Diagnostic tool for Breast Cancer Patient
Background: Breast cancer is the most common type of cancer in women demanding accurate diagnosis to take remedial measures to treat.Objective: Comparing the diagnostic capability of the computer regulation thermography (CRT), as a novel and safe diagnostic procedure, with common methods including sonography, mammography and clinical examinations for diagnosing breast cancer in suspicious...
متن کاملA Deep Model for Super-resolution Enhancement from a Single Image
This study presents a method to reconstruct a high-resolution image using a deep convolution neural network. We propose a deep model, entitled Deep Block Super Resolution (DBSR), by fusing the output features of a deep convolutional network and a shallow convolutional network. In this way, our model benefits from high frequency and low frequency features extracted from deep and shallow networks...
متن کاملExperimental Study on the Effect of monitor height on Eye Indices Influencing Eye Discomfort among VDT Workers
Introduction: Nowadays, excessive computer use in the workplace has raised concerns about the health status of VDT workers, particularly complaints about eye discomforts. Due to the importance of the eyelids and eye closure parameters on eye health during computer works and the direct effect of monitor height on these parameters, this study was aimed to examine the effect of different monitor h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neuroscience methods
دوره 174 1 شماره
صفحات -
تاریخ انتشار 2008