Simplified [correction of Simlified] calculation of mean QRS vector (mean electrical axis of heart) of electrocardiogram.
نویسندگان
چکیده
In clinical practice assessment of the mean QRS axis (MQRSA) provides information related either with hypertrophy of the ventricles or conduction blocks. The method adopted by clinicians i.e. the inspection of the QRS voltage in six of the limb leads has inherent element of subjectivity of approximately 10degrees. Moreover, in certain condition, when there is ambiguity about differentiation of left axis deviation assessed by inspection method in to either hypertrophy of left ventricles or complete/hemi block of the left bundle branches, accurate measurement of the axis becomes necessary to arrive at the correct diagnosis. Though a formula based on area under R wave and S-wave of the same QRS complex has been derived for accurate measurement of axis, considering its use in the computer software, working with ordinary electrocardiograph the only method for accurate measurement of the QRS axis is plotting method i. e. the net voltages in Lead-I, and III on their respective axes which is not practicable in clinical settings. Although, calculation of MQRSA by area method gives an accurate assessment of MQRSA, some authors prefer measurement of axis by voltage method, as in cases of the right ventricular hypertrophy with a broad S-wave calculation of axis by area method may give erroneous results. Hence, to obtain correct measurement of MQRSA, we have derived a simplified formula based on the net voltage of QRS complexes in Lead-I and Lead-III. The formula derived is as follows, Tan(theta) =(I + 2III) divided by sqrt [3I], where I and III represent net voltage in Lead-I and III, theta = angle subtended with the axis Lead-I. The value of theta can be found by using scientific calculator or the table. In case net voltage of QRS complex in Lead-I being negative, the value of the theta should be subtracted from 180degrees to find the angle of mean QRS vector.
منابع مشابه
Effects of tramadol on electrocardiogram, mean electrical axis and respiration in Kagani goats (Capra hircus)
The effects of tramadol on electrocardiogram (ECG), mean electrical axis and respiratory rates were studied in adult kagani goats after intramuscular administration of tramadol at 1 mg/kg b.wt. as a prelude to its clinical use as an analgesic in veterinary practice. The ECG was monitored by standard bipolar leads and discernible electrocardiographic features were observed in lead II. The normal...
متن کاملElectrocardiogram of Clinically Healthy Mithun (Bos frontalis): Variation among Strains
A study was conducted to establish the normal electrocardiogram in four different genetic strains of mithun (Bos frontalis). Electrocardiography, cardiac electrical axis, heart rate, rectal temperature and respiration rate were recorded in a total of 32 adult male mithun of four strains (n = 8 each). It was found that the respiration and heart rates were higher (P < .05) in Manipur than other t...
متن کاملEffects of intracerebroventricular injection of histamine and H1, H2 receptor antagonists on electrocardiographic parameters in broiler chickens
The aim of this study was to assess the effects of exogenous histamine and H1 and H2 central receptorson electrocardiographic (ECG) parameters, heart rate and mean electrical axis in broiler chickens. For thispurpose, Ross broiler chickens (750-800 g weight) received intracerebroventricularly (ICV) histamine.Moreover, to determine the receptors involved in histamine-induced alterations in ECG c...
متن کاملThe Study of ECG Changes in Humans Exposed to 50 Hz Electromagnetic Fields
Introduction: It has been reported that cardiovascular effects are among the possible health effects of being exposed to extremely low frequency electromagnetic fields (ELF EMSs). Material and Methods: This study has been conducted to evaluate the long term effects of exposure to magnetic and electric fields on electrocardiogram signal changes. Nine power transmission posts having different vol...
متن کاملRelationship between the electrocardiogram and the position of the heart as determined by biplane angiocardiography.
O VER 50 years ago, Waller pointed out the obvious correlation between anatomic and electrical phenomena, the mirror image electrocardiogram in situs inversus.' Shortly thereafter, Einthoven described other correlations between the position of the heart and the mean electrical axis in normal human subjects.2 These correlations were extended to hypertrophied hearts by Groedel and Monckeberg in 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Indian journal of physiology and pharmacology
دوره 47 2 شماره
صفحات -
تاریخ انتشار 2003