The effect of multiple processing and re-use on orthodontic mini-screw torque values

نویسندگان

  • Saeed Noorollahian
  • Shiva Alavi
  • Elahe Rafiei
چکیده

BACKGROUND Reusing orthodontic mini-screws would reduce treatment cost and lead to more use of mini-screws and improvement of orthodontic treatments. This study has assessed the effects of reprocessing and reusing the titanium mini-screws on their maximum insertion, removal and fracture torque (FT). MATERIALS AND METHODS In this experimental study, 20 titanium mini-screws (1.6-mm × 8-mm) were randomly divided into two equal groups. In the test group, the screws were first sterilized by autoclave and then their FT was assessed. In the control group, FT was assessed after 5 times of insertion, cleaning, processing (37% phosphoric acid for 10 min, 5.25% sodium hypochlorite for 30 min) and sterilizing with autoclave. The maximum insertion and removal torque values were compared using the repeated measure ANOVA and the FT data were analyzed by the t-test. The data were analyzed using the SPSS software (version 13.0) and the significance was set on 0.05. RESULTS The paired t-test for maximum insertion torque (MIT) showed that MIT1 was significantly lower than other MIT values (P = 0.02) and also MIT2 was significantly higher than MIT5 (P = 0.01), but other MIT values had no significant differences. The paired t-test for maximum removal torque (MRT) showed that only MRT2 was significantly higher than other MRT values (except MRT1) (P = 0.046). Regarding FT, the t-test showed that there was no significant difference between FT0 and FT5 (P = 0.485). CONCLUSION Within limitations of this study, five time insertion, cleaning, processing and steam sterilization had no significant negative effect on insertion, removal and FT of the mini-screws.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of insertion angle on orthodontic mini-screw torque

BACKGROUND Primary stability is an important factor for the clinical success of orthodontic mini-screws. The present study made an attempt to evaluate the effect of insertion angle changes on the maximum insertion and removal torque of orthodontic mini-screws. MATERIALS AND METHODS In this experimental study, 72 mini-screws (Dual Top Anchor System, Jeil, 1.6 mm diameter, 8 mm length) were use...

متن کامل

Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver

Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one...

متن کامل

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

Clinical indices for orthodontic mini-implants.

Orthodontic mini-implants were recently developed and have been widely used in clinics. However, loosening of mini-implants, as well as infection and swelling of mucosal tissue at the placement site, are often observed during orthodontic treatment. Thus, clinical indices are greatly needed for the safe use of orthodontic mini-implants. This article presents information on mini-implants and offe...

متن کامل

Use of palatally inserted mini-screw for upper molar distalization: A case series

 Abstract Reports have shown that molars can be distalized successfully with virtually no orthodontic anchorage loss with an intraosseous anchorage, even with fully erupted second molars. The purpose of this study was evaluating the effects of mini-screws as skeletal anchorage for upper molar distalization. In this case series, three patients needing maxillary first molar distalization,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2015