Solubility of freon-22 in blood and lung tissue.

نویسندگان

  • P J Franks
  • R H Hooper
  • P R Jones
چکیده

Despite the frequent use of freon-22 (e.g. to measure pulmonary blood flow), there is no agreement on its solubility in water or body fluids. The values in the literature vary, often quoted without reference to measurement or identification as Ostwald or Bunsen coefficients. We used a Schölander apparatus and determined the Bunsen solubility coefficient (mlgas.(mlfluid.atmosphere)-1) at 37 degrees C as: 0.476 in water; 0.673 in human whole blood; 0.479 in human plasma; 0.662 in canine whole blood; 0.437 in canine plasma; and 1.077 in homogenized canine lung tissue. As pure freon was used, these solubilities may not be applicable if freon-22 does not obey Henry's law. In man, the Ostwald solubility coefficient is calculated as 0.76 ml/ml whole blood at BTPS. These results provide information for further studies involving freon-22, and clear the confusion which has arisen from poorly defined solubility coefficients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An accidental death due to Freon 22 (monochlorodifluoromethane) inhalation in a fishing vessel.

A case of accidental Freon 22 (monochlorodifluoromethane) poisoning in a fishing vessel is reported. Forensic autopsy revealed severe pulmonary edema and congestion (left lung; 576 g, right lung; 740 g). GC-MS analysis clearly showed that the deceased inhaled Freon 22 gas prior to his death. Freon 22 concentration was 169+/-7.0 microg/ml in the heart blood. The distribution pattern of Freon 22 ...

متن کامل

Comparison of estimates of cardiac output by indicator dilution and freon 22 uptake during gas mixing in dogs.

STUDY OBJECTIVE The aim was to measure cardiac output while rebreathing tidal volumes, by correction of soluble gas uptake for gaseous mixing. DESIGN Simultaneous measurements of cardiac output by indocyanin green and freon 22 uptake during rebreathing were made. Mixing for a hypothetical gas of identical gaseous diffusivity to freon 22 was calculated by interpolation between concentrations o...

متن کامل

Cerebral blood flow measured by NMR indicator dilution in cats.

We developed techniques to assess the utility of a nuclear magnetic resonance (NMR) indicator for cerebral blood flow studies in cats, using Freon-22 for the first candidate. A PIN-diode-switched NMR experiment allowed the acquisition of an arterial as well as a cerebral fluorine-19 signal proportional to concentration vs. time in a 1.89 T magnet. Mean +/- SD blood:brain partition coefficients ...

متن کامل

s . in s - de t ] 1 7 A pr 2 00 0 EFFICIENCY OF NEUTRON DETECTION OFSUPERHEATED DROPS OF FREON - 22

Neutron detection efficiency of superheated drops of Freon-22 for neutrons obtained from a 3 curie Am-Be neutron source has been reported in this paper. Although Freon-22 having lower boiling point than many other similar liquids (e.g.Freon-12, Freon-114, Isobutane) is expected to be more sensitive to neutrons ,it has not been reported so far and therefore this paper constitutes the first repor...

متن کامل

Histological Evaluation of the Fetus Lung in NMRI Mice after Exposure to Iron Oxide Nanoparticles: an in vitro Study

Background and Aim: Iron oxide nanoparticles are used in fields related to nanotechnology including ecology, magnetic storage, imaging and medicinal purposes. Iron nanoparticles produce reactive oxygen species (Ros). These materials are able to cross the placenta. The aim of this study was to investigate toxic effect of iron oxide nanoparticles on fetal lung in mice. <br ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 62 4  شماره 

صفحات  -

تاریخ انتشار 1989