Retrospective evaluation of exposure index (EI) values from plain radiographs reveals important considerations for quality improvement
نویسندگان
چکیده
INTRODUCTION Following X-ray exposure, radiographers receive immediate feedback on detector exposure in the form of the exposure index (EI). PURPOSE To identify whether radiographers are meeting manufacturer-recommended EI (MREI) ranges for routine chest, abdomen and pelvis X-ray examinations under a variety of conditions and to examine factors affecting the EI. METHODS Data on 5000 adult X-ray examinations including the following variables were collected: examination parameters, EI values, patient gender, date of birth, date and time of examination, grid usage and the presence of implant or prosthesis. Descriptive statistics were used to summarize each data set and the Mann-Whitney U test was used to determine significant differences, with P < 0.05 indicating significance for all tests. RESULTS Most examinations demonstrated EI values that were outside the MREI ranges, with significantly higher median EI values recorded for female patient radiographs than those for male patients for all manufacturers, indicating higher detector exposures for all units except for Philips digital radiography (DR), where increased EI values indicate lower exposure (P = 0.01). Median EI values for out of hours radiography were also significantly higher compared with normal working hours for all technologies (P ≤ 0.02). Significantly higher median EI values were demonstrated for Philips DR chest X-rays without as compared to those with the employment of a grid (P = 0.03), while significantly lower median EI values were recorded for Carestream Health computed radiography (CR) chest X-rays when an implant or prosthesis was present (P = 0.02). CONCLUSIONS Non-adherence to MREIs has been demonstrated with EI value discrepancies being dependent on patient gender, time/day of exposure, grid usage and the presence of an implant or prosthesis. Retrospective evaluation of EI databases is a valuable tool to assess the need of quality improvement in routine DR.
منابع مشابه
Evaluation of the Influence of Exposure Index on Image Quality and Radiation Dose
Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...
متن کاملEvaluation of digital radiography practice using exposure index tracking
Some digital radiography (DR) detectors and software allow for remote download of exam statistics, including image reject status, body part, projection, and exposure index (EI). The ability to have automated data collection from multiple DR units is conducive to a quality control (QC) program monitoring institutional radiographic exposures. We have implemented such a QC program with the goal to...
متن کاملThe Utility of Plain Radiography in the Evaluation of Degenerative Spine Disease
Study Designs: Questionnaire, Retrospective chart review, Cadaver study, and crosssectional study. Objectives: Assess current imaging practices; determine utility of accessory radiographic studies, including dynamic and oblique radiographs; calculate effective radiation doses of routine spine radiographs. Summary of Background Data: Plain radiography is generally considered the initial imaging ...
متن کاملEvaluation of Groundwater Resources Quality and Its Effect on soil permeability in Borujerd-Doroud Plain Using statistical and geostatistical analysis
Introduction: Considering the increasing population and the growing need for food and drinking water, it is essential to explore and understand the factors of crop production, especially water resources. Today, the removal of undiluted water from underground water sources has produced qualitative issues, in addition to a few shortcomings. These issues are more significant in arid and semi-arid ...
متن کاملEvaluation of the Water Quality Pollution Indices for Groundwater Resources of Ghahavand Plain, Hamadan Province, Western Iran
Background: Due to the increasing pollution of water resources, this study was carried out for evaluation of water quality pollution indices for monitoring of heavy metals (As, Zn, Pb and Cu) contamination in Ghahavand Plain, Hamadan Province, Western Iran during spring and summer 2012. Methods: Totally, 20 ground water wells were chosen randomly. The samples were filtered (0.45 μm) and m...
متن کامل