Quantification of growth hormone in serum by isotope dilution mass spectrometry.

نویسندگان

  • Cristian G Arsene
  • André Henrion
  • Nina Diekmann
  • Jenny Manolopoulou
  • Martin Bidlingmaier
چکیده

Interassay variation of antibody-based routine tests hampers comparability of measurement results for growth hormone (GH) between different laboratories and decision making in clinical practice. Here it is demonstrated that quantification of GH by isotope dilution mass spectrometry (IDMS) constitutes a way to obtain precise and reliable results that can be referred to in evaluation of performance of commercial test kits. With the IDMS method developed, tryptic cleavage products YSFLQNPQTSLCFSESIPTPSNR (T6) and LEDGSPR (T12) of GH are quantified by liquid chromatography tandem mass spectrometry (LC-MS/MS) using isotopically labeled forms of the peptides as internal standards. The GH cleavage fragments are obtained by whole serum tryptic proteolysis and then extracted from the resulting mixture by semipreparative reversed-phase LC followed by strong cation exchange chromatography. Analysis of blank serum spiked with recombinant 22-kDa GH at different concentration levels would result in a mean recovery of 101.6%, a standard deviation (SD) of 2.5%, a combined uncertainty (u(c)) of 3.0%, and a limit of quantification (LOQ) of 1.7 microg/L when quantifying T6 as a GH-derived fragment, whereas recovery=100.7%, SD=2.4%, u(c)=2.5%, and LOQ=2.7 microg/L were found with T12. The potential to acquisition of reference values is exemplified by application to serum materials used in a recent quality assessment exercise for routine laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment with Luteinizing Hormone-ReleasingHormone Antagonists: is Serum TestosteroneReduction the Only Mechanism?

Background: Androgen deprivation therapy (ADT) by surgical or medical castration is recommended for advanced or metastatic prostate cancer. Recent literature suggests that medical castration by luteinizing hormone receptor hormone (LHRH) antagonists might have advantages over treatment with LHRH agonists in patients with metastatic prostate cancer when prostate specific antigen (PSA) progressio...

متن کامل

Absolute quantification of DcR3 and GDF15 from human serum by LC-ESI MS

Biomarkers are widely used in clinical diagnosis, prognosis and therapy monitoring. Here, we developed a protocol for the efficient and selective enrichment of small and low concentrated biomarkers from human serum, involving a 95% effective depletion of high-abundant serum proteins by partial denaturation and enrichment of low-abundant biomarkers by size exclusion chromatography. The recovery ...

متن کامل

Quantification of serum and urinary S-adenosylmethionine and S-adenosylhomocysteine by stable-isotope-dilution liquid chromatography-mass spectrometry.

BACKGROUND We have developed an assay that uses stable-isotope-dilution liquid chromatography-mass spectrometry to assess S-adenosylmethionine (SAM) and S-adenosylhomocysteine (SAH) in body fluids to investigate the relationship of these metabolites to hyperhomocysteinemia. METHODS Commercially obtained SAM (D(3) methyl) and (13)C(5)-SAH uniformly labeled in the adenosyl moiety, which was syn...

متن کامل

Stable Isotope Labeling by Essential Nutrients in Cell Culture for Preparation of Labeled Coenzyme A and Its Thioesters

Stable isotope dilution mass spectrometry (MS) represents the gold standard for quantification of endogenously formed cellular metabolites. Although coenzyme A (CoA) and acyl-CoA thioester derivatives are central players in numerous metabolic pathways, the lack of a commercially available isotopically labeled CoA limits the development of rigorous MS-based methods. In this study, we adapted sta...

متن کامل

Determination of Serum Creatinine by Isotope Dilution Spectrometry with Liquid Chromatographic Separation Mass

Isotope dilution mass spectrometry with liquid chromatography for the determination of serum creatinine is studied. After adding labeled (15N2) creatinine to the serum, creatinine was isolated using high performance liquid chromatography. Measurements were performed by electron impact mass spectrometry with use of a direct insertion device. Analytical results of the NIST (formerly NBS) SRM seru...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical biochemistry

دوره 401 2  شماره 

صفحات  -

تاریخ انتشار 2010