Orbital volume augmentation for late enophthalmos using the deep lateral wall.
نویسندگان
چکیده
Orbital volume augmentation to address enophthalmos and hollowing of the superior sulcus has been described with a variety of materials and from a variety of approaches.(1-4) A common location for volume augmentation is the inferomedial orbital wall; this surface is often the one that was expanded related to orbital trauma, and it is easily accessed through hidden conjunctival or caruncular incisions.
منابع مشابه
Evaluation of computer-based volume measurement and porous polyethylene channel implants in reconstruction of large orbital wall fractures.
PURPOSE To describe the use of computer-based orbital volume measurement as a predictor of late enophthalmos, and to assess the effectiveness of the MedPor (Porex Surgical Products Group, Newnan, GA) porous polyethylene channel implant to restore orbital volume in repairing large orbital wall fractures. METHODS Sixteen patients with unilateral large orbital fractures were included. Computed t...
متن کاملOrbital Volume Augmentation with Calcium Hydroxyapatite Filler in Anophthalmic Enophthalmos
PURPOSE To report the long-term results of orbital volume augmentation using calcium hydroxyapatite filler injections in patients with anophthalmic sockets. METHODS Twelve eligible patients with post-enucleation socket syndrome (PESS) and small orbital volumes were included in our study. In this investigation, 1.5 mL injectable calcium hydroxyapatite (Radiesse) was utilized in an off-label ap...
متن کاملCombined transconjunctival and transcaruncular approach for repair of large medial orbital wall fractures.
OBJECTIVES To describe the combined transcaruncular and transconjunctival approach in isolated large medial orbital wall fractures and to study the implications of uncorrected posterior orbital volume on postoperative enophthalmos. METHODS A retrospective medical record review was performed of 23 consecutive patients who underwent reduction surgery for isolated large medial orbital wall fract...
متن کاملCorrelation between volume of herniated orbital contents and the amount of enophthalmos in orbital floor and wall fractures.
PURPOSE To analyze the correlation between the volume of herniated orbital contents and the amount of enophthalmos in orbital floor and wall fractures. MATERIALS AND METHODS Patients with secondary enophthalmos due to unilateral orbital floor and wall fractures were recruited. Computed tomography-assisted measurements of both orbits as well as of the amount of enophthalmos were performed. The...
متن کاملThree-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population
BACKGROUND The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. METHODS Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of facial plastic surgery
دوره 5 3 شماره
صفحات -
تاریخ انتشار 2003