Tartrazine Solution as Dosimeter for Gamma Radiation Measurement
نویسندگان
چکیده
In this study, Tartrazine aqueous solution was investigated as a simple low-dose dosimeter in the range of 20-500 Gy for the high ionizing radiation, gamma ray. Gradual bleaching of Tartarzine solution was observed with dose by measuring the absorbance of Tartarzine-solutions at specified wavelength, λmax = 428 nm. Tartrazine concentration (10 –4 , 5 ×10 –4 and 10 –3 M) and solution-initial pH value (5, 7 and 9) were considered as factors affecting degree of bleaching. It was found that Tartarzine-solution color was diminished gradually with selected dose range due to breakdown of the azo bond. The rate of bleaching increases with the increase of solution-initial pH. Increase of Tartarzine-concentration causes widening of range to which solution is susceptible. The post-irradiated effect (24 hours) was found to cause more bleaching. The sensitivity of Tartrazine solution is not regular with the Tartarzine-concentration and regular with pH.
منابع مشابه
Performance of Sife - Eldeen dosimeter over broad absorbed dose and dose rate ranges of γ – radiation and at different temperatures
Background: Results are presented on some dosimetric characteristics of Sife – Eldeen dosimeter based on the radiation induced conductivity (RIC) of 3.5 M aqueous urea solutions. The studied characteristics were the response (RIC) of Sife – Eldeen dosimeter in broad ranges of absorbed dose, dose rates and at different irradiation temperature. Materials and Methods: Kent EIL5007 conductivity met...
متن کاملA novel approach towards development of real time chemical dosimetry using pulsating sensor-based instrumentation
The paper presents an innovative approach towards development of real time dosimetry using a chemical dosimeter for measurement of absorbed radiation dose in the range between 1 and 400 Gy. Saturated chloroform solution in water, a well known chemical dosimeter, is used to demonstrate the concept of online measurement of radiation dose. The measurement approach involves online monitoring of inc...
متن کاملLinearity response characterization of Polystyrene/ Graphene oxide nanocomposite as real-time dosimeter for therapeutic purposes
Introduction: In recent years, one of the emerging two dimensional (2D) carbon based nano- materials namely Graphene Oxide has been incorporated into polymeric matrices to enhance the electrical properties of the composites. The electrical conductivity of Graphene Oxide is excellently used in fabricating polymer-based sensors, energy-related systems, biotechnology, anti-statics...
متن کاملEvaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife
Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...
متن کاملDimethyl sulfoxide, diethyl fumarate solution for high dose dosimetry
Background: Dosimetry is a fundamental part of the radiation processing industry. Aqueous inorganic dosimeters have been used for gamma radiation dosimetry such as standard ferrous sulfate dosimeter. The purpose of this study was to investigate the effect of gamma radiation on the diethyl fumarate DEF in dimethyl sulfoxide DMSO solution and its possible use in chemical dosimetry. Materials and ...
متن کامل