STUDY DESIGN Evaluation using 3-dimensional screw trajectory software and computed tomographic scans. OBJECTIVE To investigate the anatomic feasibility of laminar screw placement in the upper thoracic spine compared with pedicle screw placement. SUMMARY OF BACKGROUND DATA Although laminar screws have been suggested as an alternative to pedicle screws in the upper thoracic spine, previous anatomic feasibility studies have some limitations. METHODS Four types of screws were simulated from T1 to T6: unilaminar screw (US), superior bilaminar screw (SBS), inferior bilaminar screw (IBS), and pedicle screw (PS). Maximum allowable screw dimensions and the success rates of 4.5-mm screw placement were compared for each level. Laminar screw dimensions with more than 90% success rate at each level were determined for reference. RESULTS Computed tomographic scans of 132 patients were analyzed. Laminar screw diameters gradually increased from T1 (4.4-5.4 mm, for each type) to T6 (4.8-6.7 mm), whereas PS diameter steeply declined from T1 (5.9 mm) to T4 (3.4 mm) and then leveled off. At T1, PS had greater success rate of 4.5-mm screw placement than laminar screws (US > IBS > SBS); at T2, US had greater success rate than IBS, followed by PS and SBS; and at T3 to T6, laminar screws (US > IBS > SBS) had greater success rate than PS in all comparisons. Except for SBS at T1, laminar screw diameters with more than 90% success rates were between 3.5 and 5.0 mm. CONCLUSION In view of their anatomic feasibility, laminar screws can be a viable alternative to PSs in the upper thoracic spine. Particularly at T3 to T6 where the pedicle width is inherently small, the success rates of laminar screw placement were significantly and consistently higher than those of PS placement. The comparable success rates of laminar screws using commercially available screw sizes further emphasize their potential clinical use.
منابع مشابه
Accuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملC2 Anatomy for Translaminar Screw Placement Based on Computerized Tomographic Measurements
STUDY DESIGN Anatomical study. PURPOSE To evaluate the anatomy of the C2 lamina for translaminar screw placement based on computerized tomographic measurements. OVERVIEW OF LITERATURE C2 translaminar screw insertion is a novel technique for atlanto-axial fixation. The risk of vertebral artery injury can be decreased by this technique. However, a large series of anatomical studies on C2 anat...
متن کاملFree-hand placement of high thoracic pedicle screws with the aid of fluoroscopy: evaluation of positioning by CT scans in a four-year consecutive series.
OBJECTIVE To evaluate the feasibility, safety and accuracy of pedicle screw placement in the upper thoracic spine using the free-hand technique with the aid of fluoroscopy; to analyze the methods used to verify correct screw positioning intra and postoperatively. METHOD All patients with instability of the cervicothoracic or upper thoracic spine and at least one screw placed in the segment T1...
متن کاملThoracic Pedicle Screw Placement Guide Plate Produced by Three-Dimensional (3-D) Laser Printing
BACKGROUND The aim of this study was to evaluate the accuracy and feasibility of an individualized thoracic pedicle screw placement guide plate produced by 3-D laser printing. MATERIAL AND METHODS Thoracic pedicle samples of 3 adult cadavers were randomly assigned for 3-D CT scans. The 3-D thoracic models were established by using medical Mimics software, and a screw path was designed with scan...
متن کاملFree Hand Pedicle Screw Placement in the Thoracic Spine without Any Radiographic Guidance : Technical Note, a Cadaveric Study
Thoracic pedicle screw fixation techniques are still controversial for thoracic deformities because of possible complications including neurologic deficit. Methods to aid the surgeon in appropriate screw placement have included the use of intraoperative fluoroscopy and/or radiography as well as image-guided techniques. We describe our technique for free hand pedicle screw placement in the thora...