Failure Mechanisms in Embedded Planar Capacitors during High Temperature Operating Life (HTOL) Testing

نویسندگان

  • Mohammed A. Alam
  • Michael H. Azarian
  • Michael Osterman
  • Michael Pecht
چکیده

High temperature operating life (HTOL) testing was performed on embedded planar capacitors (with epoxyBaTiO3 composite dielectric) by subjecting these devices to highly accelerated temperature and voltage aging conditions. The objective of HTOL testing was to precipitate avalanche breakdown failures as a result of defects in the composite dielectric. These defects include porosity, voids, and agglomeration of BaTiO3 in the epoxy matrix and are introduced during the manufacturing process. Since these tests were conducted under highly accelerated conditions, the failure mechanisms observed may not occur under the normal operating conditions of this device. However, the results of HTOL can be used in qualification of embedded planar capacitors and to further improve manufacturing processes to reduce the number of these defects. During HTOL testing, the failure modes observed were a gradual decrease in the capacitance and a sharp decrease in the value of insulation resistance. The sharp decrease in the value of insulation resistance after some time was expected to be governed by the avalanche breakdown (ABD) of the dielectric. The ABD failures were modeled using the Prokopowicz model. The effect of the area of the capacitor and dielectric thickness on the time-to-failure as a result of ABD was also investigated. A novel failure analysis technique was developed that can be used to locate the failure site of avalanche breakdown and understand the failure mechanism in this material. This technique can also be applied to some other dielectric materials as well. It was also observed that before ABD failures the dielectric material started to show signs of degradation. These degradations were detectable using AC measurements (measurement of dissipation factor) but were not observed in DC measurements (measurement of insulation resistance).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prognostics of Failures in Embedded Planar Capacitors using Model-Based and Data-Driven Approaches

This paper presents the application of model-based and data-driven approaches for prognostics of failures in embedded planar capacitors. An embedded planar capacitor is a thin laminate that serves both as a power/ground plane and as a parallel plate capacitor in a multilayered printed wiring board. These capacitors have gained importance with an increase in the operating frequency and a decreas...

متن کامل

Prognostics of Embedded Planar Capacitors under Temperature and Voltage Aging

This paper presents the application of model-based and data-driven approaches for prognostics and health management (PHM) of embedded planar capacitors under elevated temperature and voltage conditions. An embedded planar capacitor is a thin laminate that serves both as a power/ground plane and as a parallel plate capacitor in a multilayered printed wiring board (PWB). These capacitors are typi...

متن کامل

The Effects of Different Temperatures and Temperature Cycling On Breakdown Voltages of Tantalum Capacitors

This study focuses on the effects of different temperatures and temperature cycling on breakdown voltages of tantalum capacitors. High and low temperature tests and temperature cycling tests were done. In all tests the used temperatures were inside component’s operating temperature limits. After the tests, capacitors were tested for their breakdown voltage. According to results of this research...

متن کامل

Reliability Evaluation of Liquid and Polymer Aluminum Electrolytic Capacitors

Title of Document: RELIABILITY EVALUATION OF LIQUID AND POLYMER ALUMINUM ELECTROLYTIC CAPACITORS 45BAnshul Shrivastava, Doctor of Philosophy (Ph.D.), 2014 Directed By: Professor Michael Pecht, Department of Mechanical Engineering Liquid aluminum electrolytic capacitors are known for their reliability problems. They are considered as the weakest link in the power electronics system. The liquid e...

متن کامل

Early Detection of Avalanche Breakdown in Embedded Capacitors Using Sprt

Early detection of avalanche breakdown in an embedded planar capacitor dielectric is addressed in this paper. These failures were observed during accelerated temperature and voltage aging of embedded planar capacitors. At the time of avalanche breakdown there was a sharp drop in the value of insulation resistance. There was no trend in the values of insulation resistance before failure, making ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011