Better Lesion Creation And Assessment During Catheter Ablation.

نویسندگان

  • Saurabh Kumar
  • Chirag R Barbhaiya
  • Samuel Balindger
  • Roy M John
  • Laurence M Epstein
  • Bruce A Koplan
  • Usha B Tedrow
  • William G Stevenson
  • Gregory F Michaud
چکیده

Permanent destruction of abnormal cardiac tissue responsible for cardiac arrhythmogenesis whilst avoiding collateral tissue injury forms the cornerstone of catheter ablation therapy. As the acceptance and performance of catheter ablation increases worldwide, limitations in current technology are becoming increasingly apparent in the treatment of complex arrhythmias such as atrial fibrillation. This review will discuss the role of new technologies aimed to improve lesion formation with the ultimate goal of improving arrhythmia-free survival of patients undergoing catheter ablation of atrial arrhythmias.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact Geometry Affects Lesion Formation in Radio-Frequency Cardiac Catheter Ablation

One factor which may be important for determining proper lesion creation during atrial ablation is catheter-endocardial contact. Little information is available that relates geometric contact, depth and angle, to ablation lesion formation. We present an electrothermal computer model of ablation that calculated lesion volume and temperature development over time. The Pennes bioheat equation was ...

متن کامل

Real-time magnetic resonance imaging-guided radiofrequency atrial ablation and visualization of lesion formation at 3 Tesla.

BACKGROUND Magnetic resonance imaging (MRI) allows visualization of location and extent of radiofrequency (RF) ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT -RI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. OBJECTIVE The purpose of this ...

متن کامل

The creation of linear contiguous lesions in the atria with an expandable loop catheter.

OBJECTIVES This article describes a catheter system designed to create linear atrial lesions and identifies electrophysiologic markers that are associated with the creation of linear lesions. BACKGROUND Atrial fibrillation (Afib) is the most common arrhythmia in humans and causes a significant morbidity. The success of surgical interventions has provided the impetus for the development of a c...

متن کامل

Linear atrial ablation with a diode laser and fiberoptic catheter.

The catheter maze procedure for the treatment of chronic atrial fibrillation requires the creation of transmural, continuous linear atrial lesions. Attempts to drag a conventional radiofrequency ablation catheter across the atria in clinical as well as experimental studies have resulted in discontinuous lesions. Continuous linear lesions have been most difficult to create in trabeculated atrial...

متن کامل

Characterization of the impact of catheter-tissue contact force in lesion formation during cavo-tricuspid isthmus ablation in an experimental swine model.

AIMS Catheter-tissue contact is critical for effective lesion creation. The objective of this study was to determine in an experimental swine model the pathological effects of cavo-tricuspid isthmus ablation using two systems that provide reliable measures of the pressure at the catheter tip during radiofrequency ablation procedures. METHODS AND RESULTS We performed the procedure in eight pig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of atrial fibrillation

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 2015