MO-A-213AB-04: Verification of 4D Dose Delivery Using 4D Digital Human Phantom.
نویسندگان
چکیده
PURPOSE At present, techniques of 4D dose verification in radiation therapy for lung cancers associated with respiratory motion are very limited, due to either lack of patient anatomy or breathing information. The aim of this study is to develop a 4D dose verification technique based on XCAT phantom which incorporates both patient anatomy and respiratory mechanics. MATERIALS AND METHODS The 4D-XCAT phantom which possesses patient specific anatomy and allows input of respiratory parameters was generated using an integrated Matlab program. 10-phase 4DCT, MIP, and AIP images generated from 4D-XCAT were used for designing a 3D conformal treatment plan. Real-time dose delivery was simulated by calculating the deposited dose in each phase of 4D-XCAT for each beam with fixed individual planning dose. The 4D delivered dose was determined by accumulating dose deposition of all beams in all phases using deformable image registration implemented in VelocityAl software. The planned and delivered doses were compared based on target coverage and DVHs of OARs (lungs, cord, heart, and esophagus). RESULTS Target volume coverage was 97.5% in the simulated real-time delivery, as compared to 95% as planned based on AIP. Maximum cord dose, maximum esophagus dose, mean heart dose, and V20Gy of lung were comparable between the planned and delivered dose; the relative difference were 0.3%, 4.0%, 0%, and 2.8%, respectively. These results indicates AIP-based planning was a close representation of the real 4D dose delivery for both target and OARs when the breathing pattern is regular and reproducible. CONCLUSION A framework has been successfully established for verifying 4D dose delivery using the 4D-XCAT phantom and deformable image registration. This verification method is capable of incorporating specific patient anatomy and respiratory mechanics.
منابع مشابه
An Integrated Simulation System Based on Digital Human Phantom for 4D Radiation Therapy of Lung Cancer
Purpose: To develop and test an integrated simulation system based on the digital Extended Cardio Torso (XCAT) phantom for 4-dimensional (4D) radiation therapy of lung cancer. Methods: A computer program was developed to facilitate the characterization and implementation of the XCAT phantom for 4D radiation therapy applications. To verify that patient-specific motion trajectories are reproducib...
متن کاملA feasibility study of dynamic verification for tumor target delineation and dose delivery using a six degrees of freedom motion phantom
Background: The dynamic phantom is one of the best tools to study the impact of motion on tumor target delineation and absorbed dose verification during dose delivery. Materials and Methods: this study, a 6-DOF (degrees of freedom) phantom was designed following the stacked serial kinematics and assembled by six commercial motion stages to generate 6-DOF motion, which were RotX (pitch, around X...
متن کامل4D VMAT planning and verification technique for dynamic tracking using a direct aperture deformation (DAD) method
We developed a four-dimensional volumetric modulated arc therapy (4D VMAT) planning technique for moving targets using a direct aperture deformation (DAD) method and investigated its feasibility for clinical use. A 3D VMAT plan was generated on a reference phase of a 4D CT dataset. The plan was composed of a set of control points including the beam angle, MLC apertures and weights. To generate ...
متن کاملSU-E-J-175: A Patient-Specific 4D Digital Phantom for Dynamic Dose Estimation of External Ionizing Radiation.
PURPOSE To develop a realistic yet flexible 4D digital phantom based on patient anatomy for dynamic estimation of organ doses due to external ionizing radiation. METHODS In this work, we propose to build a 4D digital phantom based on patient CT anatomy and time-tagged CT information. A regional 4D-CT is first acquired on the patient around lesion with a RPM system. By binning CT information a...
متن کاملA Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part20 شماره
صفحات -
تاریخ انتشار 2012