Incremental Value of Continuous Glucose Monitoring When Starting Pump Therapy in Patients With Poorly Controlled Type 1 Diabetes
نویسندگان
چکیده
OBJECTIVE To compare the improvements in glycemic control associated with transitioning to insulin pump therapy in patients using continuous glucose monitoring versus standard blood glucose self-monitoring. RESEARCH DESIGN AND METHODS The RealTrend study was a 6-month, randomized, parallel-group, two-arm, open-label study of 132 adults and children with uncontrolled type 1 diabetes (A1C >or=8%) being treated with multiple daily injections. One group was fitted with the Medtronic MiniMed Paradigm REAL-Time system (PRT group), an insulin pump with integrated continuous subcutaneous glucose monitoring (CGM) capability, with instructions to wear CGM sensors at least 70% of the time. Conventional insulin pump therapy was initiated in the other group (continuous subcutaneous insulin infusion [CSII] group). Outcome measures included A1C and glycemic variability. RESULTS A total of 115 patients completed the study. Between baseline and trial end, A1C improved significantly in both groups (PRT group -0.81 +/- 1.09%, P < 0.001; CSII group -0.57 +/- 0.94%, P < 0.001), with no significant difference between groups. When the 91 patients who were fully protocol-compliant (including CGM sensor wear >or=70% of the time) were considered, A1C improvement was significantly greater in the PRT group (P = 0.004) (PRT group -0.96 +/- 0.93%, P < 0.001; CSII group -0.55 +/- 0.93%, P < 0.001). Hyperglycemia parameters decreased in line with improvements in A1C with no impact on hypoglycemia. CONCLUSIONS CGM-enabled insulin pump therapy improves glycemia more than conventional pump therapy during the first 6 months of pump use in patients who wear CGM sensors at least 70% of the time.
منابع مشابه
Mitigating Severe Hypoglycemia by Initiating Inpatient Continuous Glucose Monitoring for Type 1 Diabetes Mellitus.
Continuous glucose monitoring for type 1 diabetes mellitus will go forward for refinement as a systematic review. The scope of this topic, including populations, interventions, comparators, and outcomes, will be further developed in the refinement phase. When key questions have been drafted, they will be posted on the AHRQ Web site and open for public comment. To sign up for notification wh...
متن کاملContinuous glucose monitoring systems for type 1 diabetes mellitus.
BACKGROUND Self-monitoring of blood glucose is essential to optimise glycaemic control in type 1 diabetes mellitus. Continuous glucose monitoring (CGM) systems measure interstitial fluid glucose levels to provide semi-continuous information about glucose levels, which identifies fluctuations that would not have been identified with conventional self-monitoring. Two types of CGM systems can be d...
متن کاملارتباط بین فاکتور رشد شبه انسولین- 1 و هموگلوبین گلیکوزیله در بیماران دیابتی نوع 1
Diabetes is a common endocrine disease with complications such as retinopathy, nephropathy and neuropathy which has its monitoring through biomarkers desirable. At present, glycosylated hemoglobin (HbAic) is used for monitoring the long term control of glucose levels in diabetic patients. However, absence of a standardized range, has led to investigations that recently have suggested insulin-li...
متن کاملThe JDRF CCTN CGM TIME Trial: Timing of Initiation of continuous glucose Monitoring in Established pediatric type 1 diabetes: study protocol, recruitment and baseline characteristics
BACKGROUND Continuous glucose monitoring (CGM) has been shown to improve glucose control in adults with type 1 diabetes. Effectiveness of CGM is directly linked with CGM adherence, which can be challenging to maintain in children and adolescents. We hypothesize that initiating CGM at the same time as starting insulin pump therapy in pump naïve children and adolescents with type 1 diabetes will ...
متن کاملCombined insulin pump therapy with real-time continuous glucose monitoring significantly improves glycemic control compared to multiple daily injection therapy in pump naïve patients with type 1 diabetes; single center pilot study experience.
OBJECTIVES This study assessed the safety and clinical effectiveness of the training protocol for initiating insulin pump therapy with real-time continuous glucose monitoring (MiniMed Paradigm REAL-Time System) in a stepwise approach on pump naive subjects with type 1 diabetes compared to a control group who remained on multiple daily injection (MDI) therapy. METHODS This was a 15-week treat-...
متن کامل