Pulmonary compliance and effective compliance in patients receiving mechanical ventilation.

نویسندگان

  • R van Veenen
  • P Barkmeijer-Degenhart
  • T W van der Mark
  • R Peset
  • H J Sluiter
  • W J Snoek
چکیده

Communications for this section will be published as space and priorities permit. The comments shoul4 not exceed 5 X words in length, with a maximum of five references; one figure or table n be printed. Exceptions may occur under particular circumstances. Contributions may include comments on articles published in this pertodical, or they may be reports of unique educational charactei’. Specific permission to publish should be cited In a covering letter or appended as a postscript.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bronchiolitis obliterans. A new form of rheumatoid lung?

I appreciate the comments of van Veenen et al. Data concerning comparison of pulmonary compliance and effective compliance in the patient receiving mechanical ventilation are needed. Good correlation between these measurements in patients with low compliance documents the simpler estimate of effective compliance as a useful monitoring tool in the patient who is receiving mechanical ventilation ...

متن کامل

مقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال در بیهوشی داخل وریدی کامل(TIVA) Comparing Air Way Resistance and Dynamic Compliance of Tracheal Tube and Laryngeal Tube in TIVA

    Background & Aim: The aim of this study was to compare air way resistance and dynamic compliance of tracheal tube and laryngeal tube in TIVA(Total Intravenous Anesthesia). Nowadays, low airway resistance and dynamic compliance improvement during the mechanical ventilation whether in ICU or during general anesthesia, especially in patients with pulmonary diseases, is a favorable purpose to c...

متن کامل

Intraoperative positive end-expiratory pressure evaluation using the intratidal compliance-volume profile.

BACKGROUND Lung-protective mechanical ventilation during general surgery including the application of PEEP can reduce postoperative pulmonary complications. In a prospective clinical observation study, we evaluated volume-dependent respiratory system compliance in adult patients undergoing ear-nose-throat surgery with ventilation settings chosen empirically by the attending anaesthetist. METH...

متن کامل

Heliox improves pulmonary mechanics in a pediatric porcine model of induced severe bronchospasm and independent lung mechanical ventilation

BACKGROUND: A helium-oxygen gas mixture (heliox) has low gas density and low turbulence and resistance through narrowed airways. The effects of heliox on pulmonary mechanics following severe methacholine-induced bronchospasm were investigated and compared to those of a nitrogen-oxygen gas mixture (nitrox) in an innovative pediatric porcine, independent lung, mechanical ventilation model. RESULT...

متن کامل

Decreased respiratory system compliance on the sixth day of mechanical ventilation is a predictor of death in patients with established acute lung injury

BACKGROUND Multiple studies have identified single variables or composite scores that help risk stratify patients at the time of acute lung injury (ALI) diagnosis. However, few studies have addressed the important question of how changes in pulmonary physiologic variables might predict mortality in patients during the subacute or chronic phases of ALI. We studied pulmonary physiologic variables...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 73 2  شماره 

صفحات  -

تاریخ انتشار 1978