Quantification of skin movements artefacts using MRI

نویسندگان

  • Lydia Yahia Cherif
  • Nadia Magnenat-Thalmann
چکیده

we present a methodology for anatomical modeling, motion tracking and skin movement quantification of the hip joint using Magnetic Resonance Imaging. First, we capture the subject’s anatomy with a static protocol and reconstruct the three-dimensional models of the hip joint. Then reflective markers are attached to the subject’s limb and a dynamic protocol is used to track their trajectories. It is known that the skin surface deforms while in motion due to muscle contraction leading to errors in trajectories estimation. In this study, the displacements of the markers relative to the underlying bone are observed and quantified in all three axes. A statistical analysis is performed on the data and a strong correlation is determined between the skin movements and the instantaneous kinematics variables of the joint especially for hip rotations. The quantification of these errors could be used as a basis for a correction procedure for hip joint kinematics. Keywords-component; hip joint; MRI, skin aretefacts, statistical analysis;

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-Time Magnetic Resonance Imaging of Temporomandibular Joint Dynamics

This study evaluated the use of a novel real-time MRI technique based on fast low angle shot (FLASH) MRI with radial encoding, gridding reconstruction, and sliding window for the assessment of temporomandibular joint (TMJ) dynamics in a cohort of 30 young volunteers without prior diagnosis of TMJ pathology. High-resolution images (0.75 0.75 mm 2 , 5 mm section thickness) were obtained at 3 fram...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

Quantification of Soft Tissue Artefacts Using Motion Capture Data and Ultrasound Depth Measurements

The centre of rotation of the hip joint is needed for an accurate simulation of the joint performance in many applications such as pre-operative planning simulation, human gait analysis, and hip joint disorders. In human movement analysis, the hip joint center can be estimated using a functional method based on the relative motion of the femur to pelvis measured using reflective markers attache...

متن کامل

Impact of MR-safe headphones on PET attenuation in combined PET/MRI scans

BACKGROUND MR headphones are attenuation sources affecting PET quantification in hybrid PET/MRI. Despite potentially better patient communication, usage in PET/MRI scans is not approved by the vendor. This study aims to determine the impact of headphones on PET by means of phantom and patient scans. Additionally, the perceived benefit of using headphones was evaluated. FINDINGS A cylinder pha...

متن کامل

Quantification of Thermal Energy Performance Improvement for Building Integrated Photovoltaic Double-Skin Façade Using Analytical Method

In this research, an analytical method for quantification of the thermal energy performance improvement for a building integrated photovoltaic double-skin façade has provided. The system has been suggested as a retrofit measure for an existing building in Tehran. The effect of thermal performance has been analyzed through computer-assisted developed code using engineering equation solver softwa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006