Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-Up
نویسنده
چکیده
Background—Monitoring implantable cardiac device function and patient condition is important. The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial tested the hypothesis that remote home monitoring with automatic daily surveillance (HM) is safe and effective for implantable cardioverter-defibrillator follow-up for 1 year and enables rapid physician evaluation of significant events. Methods and Results—In total, 1339 patients were randomized 2:1 to HM or conventional follow-up. Follow-up checks occurred at 3, 6, 9, 12, and 15 months after implantation. HM was used before office visits at 3 and 15 months in the HM group. At 6, 9, and 12 months, HM only was used but was followed by office visits if necessary. Conventional patients were evaluated with office visits only. Scheduled office visits and unscheduled evaluations, incidence of morbidity, and time elapsed from first event occurrence in each patient to physician evaluation were tracked for each group. HM and conventional patients were similar (age, 63.3 12.8 versus 64.0 12.1 years; gender, 72.0% versus 73.1% male; New York Heart Association class II, 55.9% versus 60.4%; pathology: left ventricular ejection fraction, 29.0 10.7% versus 28.5 9.8%; coronary artery disease, 64.8% versus 71.7%; primary prevention indication, 72.2% versus 73.8%; and dual-chamber implants, 57.8% versus 56.6%). HM reduced total in-hospital device evaluations by 45% without affecting morbidity. In the HM group, 85.8% of all 6-, 9-, and 12-month follow-ups were performed remotely only, indicating that HM provided sufficient assessment in the majority. Median time to evaluation was 2 days in the HM group compared with 36 days in the conventional group (P 0.001) for all arrhythmic events. Conclusions—HM is safe and allows more rapid detection of actionable events compared with conventional monitoring in patients with implantable electronic cardiac devices. Clinical Trials Registration—URL: http:/www.clinicaltrials.gov. Unique identifier: NCT00336284. (Circulation. 2010;122:325-332.)
منابع مشابه
Remote Monitoring of Implantable Cardioverter-Defibrillator Therapy
With increasing awareness of the indications of implantable cardioverter defibrillator (ICD) therapy, the number of patients with ICDs has been growing rapidly. Patient with an ICD require high-quality care and intense follow-up to ensure safe and effective device performance. Given the expanding use and the complexity of these devices, there has been an urgent need to improve the safety and co...
متن کاملArrhythmia/Electrophysiology Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-Up The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) Trial
Background—Monitoring implantable cardiac device function and patient condition is important. The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial tested the hypothesis that remote home monitoring with automatic daily surveillance (HM) is safe and effective for implantable cardioverter-defibrillator follow-up for 1 year and enables rapid physician evaluation of significant e...
متن کاملEfficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: the Lumos-T Safely Reduces Routine Office Device Follow-up (TRUST) trial.
BACKGROUND Monitoring implantable cardiac device function and patient condition is important. The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial tested the hypothesis that remote home monitoring with automatic daily surveillance (HM) is safe and effective for implantable cardioverter-defibrillator follow-up for 1 year and enables rapid physician evaluation of significant e...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملContributions of remote monitoring to the follow-up of implantable cardioverter–defibrillator leads under advisory
AIMS Automatic daily transmission of data from implantable cardioverter-defibrillators (ICDs) enables the remote monitoring of device status and leads function. We report on a 2-year experience with remote monitoring in 40 recipients of high-voltage ICD leads, prone to fracture and under advisory since October 2007. METHODS AND RESULTS The ICDs were remotely monitored as well as systematicall...
متن کامل