Vernier Acuity with Non-simultaneous Targets: The Cortical Magnification Factor Estimated by Psychophysics

نویسندگان

  • Bettina L. Beard
  • Dennis M. Levi
  • Stanley A. Klein
چکیده

The eccentricity at which peripheral thresholds double their foveal value (E2) may relate to the visual system's anatomical organization. Using a variety of experimental approaches, previous estimates of E2 for vernier acuity have ranged from less than 0.1 deg to greater than 15.0 deg. This broad range of values seems to challenge the usefulness of E2 for determining visual topography. We explain that the varying contributions from at least two different regimes, spatial filter and local sign, may explain the broad range of E2 values found previously. We attempt to limit responses to the local sign regime, where it may be possible to determine the psychophysical analog to the gradient of the cortical spatial grain. In our experiments we measure how vernier task performance falls off with eccentricity. We hypothesize that if the vernier features are adequately separated in time, they will fall outside of the spatial filter's temporal integration span and the local sign regime would then predominate for precise positional processing. Using an interstimulus interval ranging from 20 to 200 msec between the two vernier features, we estimate that vernier thresholds in the local sign regime double at about 0.8 +/- 0.2 deg eccentricity, which is similar to anatomical estimates of the eccentricity at which the linear spacing of human cortical units doubles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cortical Magnification within Human Primary Visual Cortex Correlates with Acuity Thresholds

We measured linear cortical magnification factors in V1 with fMRI, and we measured visual acuity (Vernier and grating) in the same observers. The cortical representation of both Vernier and grating acuity thresholds in V1 was found to be roughly constant across all eccentricities. We also found a within-observer correlation between cortical magnification and Vernier acuity, further supporting c...

متن کامل

Detection of Amblyopia Using Sweep VEP Vernier and Grating Acuity

Purpose Vernier and grating acuity can be measured with swept-parameter visual evoked potentials (sVEP). However, whether sVEP Vernier and grating acuities are comparable in predicting letter acuity has not been systematically evaluated. This study evaluated the validity and reliability of sVEP Vernier and grating acuity for the detection of amblyopia in adults. Methods Three types of acuity ...

متن کامل

Contrast thresholds for identification of numeric characters in direct and eccentric view.

Aubert and Foerster (1857) are frequently cited for having shown that the lower visual acuity of peripheral vision can be compensated for by increasing stimulus size. This result is seemingly consistent with the concept of cortical magnification, and it has been confirmed by many subsequent authors. Yet it is rarely noted that Aubert and Foerster also observed a loss of the "quality of form." W...

متن کامل

Vernier acuity, crowding and cortical magnification.

When a vernier target is flanked by optimally positioned lines, foveal vernier discrimination is strongly degraded (Westheimer and Hauske, 1975). We confirmed this observation (Experiment I) and have mapped out a 2 dimensional "perceptive field" for crowding in the fovea using a 2 dot target (Experiment II). Crowding was also measured in peripheral vision, using either small flanking dots as ma...

متن کامل

Cortical sources of Vernier acuity in the human visual system: An EEG-source imaging study

Vernier acuity determines the relative position of visual features with a precision better than the sampling resolution of cone receptors in the retina. Because Vernier displacement is thought to be mediated by orientation-tuned mechanisms, Vernier acuity is presumed to be processed in striate visual cortex (V1). However, there is considerable evidence suggesting that Vernier acuity is dependen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 37  شماره 

صفحات  -

تاریخ انتشار 1997