Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography

نویسندگان

  • Giovanni Minardi
  • Carla Manzara
  • Vittorio Creazzo
  • Daniele Maselli
  • Giovanni Casali
  • Giovanni Pulignano
  • Francesco Musumeci
چکیده

BACKGROUND The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE) hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm) in relatively aged patients at mean 24 months follow-up. METHODS AND RESULTS The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 +/- 7.3 years). All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 microg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min). The following parameters were evaluated at rest and/or under DSE: heart rate (HR), ejection fraction (EF), cardiac output (CO), peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG), effective orifice area (EOA), indexed EOA (EOAi), left ventricular mass (LVM), indexed LVM (LVMi), Velocity Time Integral at left ventricular outflow tract (VTI LVOT) and transvalvular (Aortic VTI), Doppler velocity index (DVI). At rest MxPG and MnPG were 29.2 +/- 7.1 and 16.6 +/- 5.8 mmHg, respectively; EOA and EOAi resulted 1.14 +/- 0.3 cm(2) and 0.76 +/- 0.2 cm(2)/m(2); DVI was normal (0.50 +/- 0.1). At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 +/- 43 g and 157.4 +/- 27.7 g/m(2) to 191 +/- 23.8 g and 114.5 +/- 10.6 g/m(2), respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 +/- 2 1.9 mmHg), MnPG (up to 43.2 +/- 12.7 mmHg). EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 +/- 0.4 cm(2), 0.75 +/- 0.3 cm(2)/m(2) and 0.48 +/- 0.1 respectively). Two patients developed significant intraventricular gradients. CONCLUSION These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic performance at rest and under DSE, with full utilization of its available orifice, suggesting that a possible mild prosthesis-patient mismatch is not an issue of clinical relevance when this small prosthesis is used. Rest and Dobutamine stress echocardiography is a useful and effective means for evaluating prosthesis hemodynamics and for monitoring the expected LVH regression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Scandinavian multicenter hemodynamic evaluation of the SJM Regent aortic valve

BACKGROUND 112 patients who received small and medium sized St. Jude Regent heart valves (19-25 mm) at 7 Scandinavian centers were studied between January 2003 and February 2005 to obtain non-invasive data regarding the hemodynamic performance at rest and during Dobutamine stress echocardiography (DSE) testing one year after surgery. MATERIAL AND METHODS 46 woman and 66 men, aged 61.8 ± 9.7 (...

متن کامل

Pii: S1010-7940(02)00071-4

Objective: Doppler echocardiographic evaluation of prosthetic heart valve function is usually performed at rest although this situation is not representative of patients’ daily activities. Following aortic valve replacement, patients most likely to remain symptomatic are those with a small aortic root and dobutamine or exercise echocardiography has been proposed to elicit the presence of abnorm...

متن کامل

A case of aortic valve replacement with St. Jude Medical Regent valve (first implant in Japan).

The St. Jude Medical (SJM) Regent valve was developed as a new mechanical valve by improving the conventional SJM valve. The effective orifice area is wider than that of Hemodynamic Plus (HP) series. The efficacy of the new valve has been reported in Europe and the United States. On October 26, 2004, we first performed aortic valve replacement (AVR) with the SJM Regent valve for aortic valve st...

متن کامل

Hemodynamic Alterations Induced by Isoproterenol and Pacing After Aortic Valve Replacement with the Bjork-Shiley or St. Jude Medical Prosthesis

Stress evaluation was carried out in 26 patients approximately 7 months after aortic valve replacement with Bjork-Shiley valves (13 patients) and St. Jude medical valves (13 patients). During isoproterenol infusion (0.3 gg/kg/min), cardiac output increased by a factor of 1.5 and aortic valve area decreased by 50% for both valve groups, while transvalvular gradients (rest: 7 ± 2 vs 10 ± 5 mm Hg,...

متن کامل

Hemodynamics alterations induced by isoproterenol and pacing after aortic valve replacement with the Björk-Shiley or St. Jude medical prosthesis.

Stress evaluation was carried out in 26 patients approximately 7 months after aortic valve replacement with Björk-Shiley valves (13 patients) and St. Jude medical valves (13 patients). During isoproterenol infusion (0.3 micrograms/kg/min), cardiac output increased by a factor of 1.5 and aortic valve area decreased by 50% for both valve groups, while transvalvular gradients (rest: 7 +/- 2 vs 10 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Cardiothoracic Surgery

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2006