Biodegradable Mg/HA/TiO2 Nanocomposites Coated with MgO and Si/MgO for Orthopedic Applications: A Study on the Corrosion, Surface Characterization, and Biocompatability

نویسندگان

  • Shahrouz Zamani Khalajabadi
  • Aminudin Bin Haji Abu
  • Norhayati Ahmad
  • Mohammed Rafiq
  • Abdul Kadir
  • Ahmad Fauzi Ismail
  • Rozita Nasiri
  • Waseem Haider
چکیده

In the field of orthopedics, magnesium (Mg) and magnesium-based composites as biodegradable materials have attracted fundamental research. However, the medical applications of magnesium implants have been restricted owing to their poor corrosion resistance, especially in the physiological environment. To improve the corrosion resistance of Mg/HA/TiO2 nanocomposites, monolayer MgO and double-layer Si/MgO coatings were fabricated layer-by-layer on the surface of a nanocomposite using a powder metallurgy route. Then, coating thickness, surface morphology, and chemical composition were determined, and the corrosion behavior of the uncoated and coated samples was evaluated. Field-emission scanning electron microscopy (FE-SEM) micrographs show that an inner MgO layer with a porous microstructure and thickness of around 34 μm is generated on the Mg/HA/TiO2 nanocomposite substrate, and that the outer Si layer thickness is obtained at around 23 μm for the double-layered coated sample. Electrochemical corrosion tests and immersion corrosion tests were carried out on the uncoated and coated samples and the Si/MgO-coated nanocomposite showed significantly improved corrosion resistance compared with uncoated Mg/HA/TiO2 in simulated body fluid (SBF). Corrosion products comprising Mg(OH)2, HA, Ca3(PO4)2, and amorphous CaP components were precipitated on the immersed samples. Improved cytocompatibility was observed with coating as the cell viability ranged from 73% in uncoated to 88% for Si/MgO-coated Mg/HA/TiO2 nanocomposite after nine days of incubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تولید و بررسی رفتار خوردگی پوشش اکسیدهای فلزی مخلوط Al2O3/MgO/TiO2 به روش سل- ژل روی زیرلایه آلومینیم

In this study, mixed metal oxides Al2O3/MgO/TiO2 coatings with Al/Mg/Ti ratios of 5:1:3 and 2.5:3:4 were coated on AA1100 aluminum by sol-gel method. The surface morphology, phase analysis and the corrosion behavior of the Al2O3/MgO/TiO2 coatings were characterized by scanning electron microscope (SEM), X-ray diffraction (XRD), and electrochemical impedance spectroscopy measurements (EIS) in 3....

متن کامل

Evaluation of the Influence of the Number of Laser Shots on the Characterization of TiO2/MgO Nanocomposites

         The objectives of this work is to synthesize TiO2/MgO nanocomposites using a pulse laser deposition technique. At a vacuum pressure of 2.5 10-2 mBar, TiO2/MgO nanocomposites were synthesized on substrates with a laser power of 600 mJ and a wavelength of 1064 nm. This search utilizes various pulses (500, 600, and 700) at a 6-Hertz repetition rate. X-ray diffraction was utilized to inves...

متن کامل

Characterization and Corrosion Behavior of Hydroxyapatite- Coated Titanium Substrates Prepared Through Laser Induced Liquid Deposition Technique

Titanium and titanium alloys are often used in orthopedic surgery and dentistry because of their especial characteristics such as biocompatibility, mechanical properties, and corrosion resistance. However, their bio- inertness is the most serious drawback for biomedical applications. Therefore, a bioactive coating like hydroxyapatite (HA) is coated on their surface. In this regard, in the prese...

متن کامل

Synthesis and Structural Properties Characterization of HA/Alumina and HA/MgO Nanocomposite for Biomedical Applications

HAAlumina nanocomposite is biocompatible and has desirable mechanical and physical properties. Less cost, simple synthesis method, and fast production are the added advantages of this nanocomposite. Thus HA coatings on the surface of alumina substrates are used to combine excellent bioactivity of HA with superior mechanical properties of the alumina substrates. One of the elements associated wi...

متن کامل

Synthesis and characterization of nHA-PLA composite coating on stainless steel by dip-coating process for biomedical applications

316L stainless steel is the most commonly used metallic material in the manufacture of orthopedic implants. To achive better properties metal implants often coated with biocomposites. A sol–gel method was used for coating of Poly lactic acid (PLA)/Hydroxyapatite nanopowder (nHA) on stainless steel 316L substrate. The X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017