Traditional, forgotten and new left ventricular systolic function parameters on a 64-row multidetector cardiac computed tomography: a reproducibility study.
نویسندگان
چکیده
BACKGROUND Multidetector computed tomography angiography (MDCT) can provide data regarding cardiac function if a retrospective scanning is applied. We aimed at examination of the reproducibility of traditional and more sensitive parameters of the left ventricular (LV) contractility by means of a 64-row CT in order to establish errors of measurement and to determine limits that allow for a reliable detection of their changes. METHODS AND RESULTS A random sample of 25 individuals, including 15 females (aged 64 ± 13 years) and 10 males (54 ± 13 years), who had MDCT examination were retrospectively included in this study. Data reconstructions were performed on a dedicated workstation. In each case, axial image series were created with a 10% step from 0% to 90% of the RR interval using a 2 mm slice thickness. LV volume was determined in each phase. Detailed LV volume changes within phases were analyzed to determine the largest difference between the neighbor phases (peak ejection volume, PEV, mL) during systole and to calculate the peak ejection rate (PER i.e. PEV/phase duration [1/10th of RR interval], mL/s). The derived parameters were calculated as the PER normalized for LVEDV (PER-V, 1/s), the PER normalized for LVM (PER-M, mL/g × s) and the PER normalized for LVEDV times the PER normalized for LVM product (PER-VM, ml/g × s2). Considering the errors percentages, the respective values for intra- and inter-observer errors were around 5% and 8% for standard LV systolic measures. The percentage intra-observer errors' ranged between -7.8% and -10.8%, and the inter-observer errors' ranged between -11.8% and -15.7% for both PEV and PER. For the same reader, the percentage errors ranged between -8.7% and +11.9% for PER-V, -10% and +12.7% for PER-M and -18.2% and +24% for PER-VM. For the independent reader the corresponding values were -15.2% and +15.5%, -12.3% and +16.3%, and -26.6% and +30.9%. The intra- -class coeffi cients for repeated measurements for both the same reader (intra-observer) or independent reader (inter-observer) did reach values above 0.9 and around 0.8, respectively. CONCLUSIONS We concluded that traditional LV systolic parameters, as well as more sensitive measures of cardiac contractility could be determined reliably by means of a 64-row MDCT. The errors for global LV systolic function measures amount to about 5%, for PEV and PER about 15% and for the PER-derived parameters about 25%. The measurement errors established might help to assess the signifi cance of changes in repeated MDCT examinations.
منابع مشابه
ECG-gated multidetector-row computed tomography in the assessment of left ventricular function
An accurate quantitative and qualitative assessment of cardiac function is critical for clinical diagnosis, risk stratification, management and prognosis in patients with suspected or documented heart disease. Magnetic resonance, owing to its excellent temporal and spatial resolution, is currently considered a reference standard in the assessment of cardiac function. Multidetector-row computed ...
متن کاملCardiac chamber volumes, function, and mass as determined by 64-multidetector row computed tomography: mean values among healthy adults free of hypertension and obesity.
OBJECTIVES We derived mean values for cardiac dimensions, volumes, function, and mass in a normotensive nonobese population free of cardiovascular disease. BACKGROUND Multidetector computed tomography (MDCT) permits study of cardiac chamber size, function, and mass. Age- and gender-specific mean values are not available. METHODS A total of 103 normotensive, nonobese adults (43% women, age 5...
متن کاملMultiple atrial septal defects in multidetector-row computed tomography.
A 70-year-old-man was referred to our hospital for percutaneous closure of a secundum atrial septal defect (ASD). His transthoracic echocardiography (TTE) showed 2 left-to-right ASDs with a pulmonary/systemic flow ratio (Q p/Q s) of 1.89 and normal left ventricular function. Cardiac computed tomography (CT) using 320-detector row CT (Aquilion ONE VISION edition, Toshiba Medical Systems, Tokyo, ...
متن کاملImages and Case Reports in Heart Failure Endocardial Calcification of Left Atrium, Tracheobronchopathia Osteoplastica, and Calcified Aortic Arch in a Patient With Dyspnea
A 69-year-old female patient was admitted to our hospital for further cardiac evaluation with symptoms of dyspnea (New York Heart Association class III) and peripheral edema. Her history revealed artificial mitral valve replacement due to mitral stenosis 8 years earlier, severe chronic pulmonary hypertension, and severe tricuspid valve incompetence. Electrocardiogram showed normofrequent atrial...
متن کاملAblation of idiopathic left ventricular tachycardia using remote magnetic navigation integrated with advanced mapping.
1. García MJ, Lessick J, Hoffmann MH; CATSCAN Study Investigators. Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA. 2006;296:403-11. 2. Gaemperli O, Schepis T, Valenta I, Husmann L, Scheffel H, Duerst V, et al. Cardiac image fusion from stand-alone SPECT and CT: clinical experience. J Nucl Med. 2007;48:696-703. 3. Rubinshtein R, Gaspar T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiology journal
دوره 20 4 شماره
صفحات -
تاریخ انتشار 2013