High Resolution Single Crystal Scintillator Plates Used for Light Weight Material X-Ray Radiography

نویسندگان

  • Jan TOUS
  • Karel BLAZEK
  • Martin NIKL
چکیده

Recently, very thin single crystal scintillator imaging plates became of great interest. Such thin screens are mainly used in micro-CT and nano-CT systems with either micro-focus X-ray tubes or with synchrotron sources. This work deals with a high resolution CCD camera in conjunction with a macro optical system and YAG:Ce single crystal scintillators for low energy X-ray micro-radiography applications. The results show that the single crystal plates exhibit high spatial resolution and high sensitivity to low energy X-rays resulting in high image contrast. The plates are highly suitable for light-weight material X-ray radiography. The high resolution and contrast are demonstrated on single carbon fibers. Several other lightweight objects are also imaged.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

Microdome-gooved Gd(2)O(2)S:Tb scintillator for flexible and high resolution digital radiography.

A flexible microdome-grooved Gd(2)O(2)S:Tb scintillator is simulated, fabricated, and characterized for digital radiography applications. According to Monte Carlo simulation results, the dome-grooved structure has a high spatial resolution, which is verified by X-ray image performance of the scintillator. The proposed scintillator has lower X-ray sensitivity than a nonstructured scintillator bu...

متن کامل

Investigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code

Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...

متن کامل

Evaluating scintillator performance in time-resolved hard X-ray studies at synchrotron light sources

The short pulse duration, small effective source size and high flux of synchrotron radiation is ideally suited for probing a wide range of transient deformation processes in materials under extreme conditions. In this paper, the challenges of high-resolution time-resolved indirect X-ray detection are reviewed in the context of dynamic synchrotron experiments. In particular, the discussion is ta...

متن کامل

Making use of x-ray optical effects in photoelectron-, Auger electron-, and x-ray emission spectroscopies: Total reflection, standing-wave excitation, and resonant effects

Related Articles Submicron-diameter phase-separated scintillator fibers for high-resolution X-ray imaging Appl. Phys. Lett. 102, 051907 (2013) Full-field transmission x-ray imaging with confocal polycapillary x-ray optics J. Appl. Phys. 113, 053104 (2013) Large-field high-contrast hard x-ray Zernike phase-contrast nano-imaging beamline at Pohang Light Source Rev. Sci. Instrum. 84, 013707 (2013)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012