Analytical Study of Vapour Compression Refrigeration System Using Diffuser and Subcooling
نویسندگان
چکیده
This Paper Presents The Concept Of Analytical Study Ofvapour Compression Refrigeration System Using Diffuser And Subcoolingmainly Carried Out To Improve The Coefficient Of Performance Of System. To Improve The Coefficient Of Performance, It Is To Required That Compressor Work Should Decrease And Refrigerating Effect Should Increase. Initially The Diffuser Of Increasing Cross-Sectional Area Profile Was Designed, Fabricated And Introduced In Our VCR Apparatus. The Size Of Diffuser Selected Was Of 15 Degree Divergence Angle. . By Using Diffuser Power Consumption Is Less For Same Refrigerating Effect So Performance Is Improved. The Size Of The Condenser Can Also Be Reduced Due To More Heat Transfer. So Cost Of The Condenser Will Be Reduced.The Parameters Pressure And Temperature Were Measured. After Result Analysis, We Have Found That The COP Was Enhanced From2.65 To 3.38 In The Case When Conventional VCR System Was Used With Diffuser.
منابع مشابه
Parametric Study of a Vapor Compression Refrigeration Cycle Using a Two-Phase Constant Area Ejector
There are several ways of improving the performance of a vapor compression refrigeration cycle. Use of an ejector as expansion device is one of the alternative ways. The present paper aims at evaluate the performance improvement of a vapor compression refrigeration cycle under a wide range of operating conditions. A numerical model is developed and a parametric study of important parameters suc...
متن کاملاثر مادون سرد کردن مایع خروجی از کندانسور در سیستمهای تبرید ترکیبی توسط سیکل جذبی آب- آمونیاک
This paper investigates the effects of subcooling the condenser outlet refrigerant in a compression refrigeration by an absorption refrigeration in an integrated refrigeration system from energy view point. For this purpose the thermodynamic system is analyzed, base on the mass and energy equation and also the effects of operating parameters such as prime mover, ambient temperature and evaporat...
متن کاملA Comparative Performance of Freon Ejector Refrigeration Systems
This paper presents the results of the analysis of an ejector refrigeration system operating with Freons as the working substance. Such a system is suitable for operating at subzero evaporator temperatures. The mass of motive refrigerant vaoour per hour per ton and the coefficient of performance are calculated for various assumed operating parameters such as boiler temperature, evaporator temoe...
متن کاملCombined Refrigeration Cycle for Thermal Power Plant Using Low Grade Waste Steam
Now a days, In most of the thermal power plant, where low-pressure steam is being exhausted to the atmosphere as a waste steam. This waste heat could be use to operate many small preheating or cooling equipments or small scale plants. There are many refrigeration systems present for refrigeration and air condition purpose. Such as air refrigeration, vapour compression, vapour absorption etc. In...
متن کاملThermal analysis of vapour compression refrigeration system with R152a and its blends R429A, R430A, R431A and R435A
This paper presents the analysis results of R429A, R430A, R431A and R435A as drop in substitute for R152a at various evaporating temperature with condenser temperature 30°C, 40°C and 50°C. A theoretical study of thermodynamic properties such as pressure, density, and specific volume, latent heat of vaporization compression index, and critical values are done. The theoretical performance of vapo...