Biomechanical Comparison of a Simple New Hybrid External Fixator
نویسندگان
چکیده
Introduction: To determine the stiffness characteristics of a new proposed hybrid fixator in comparison with more commonly used commercialized hybrid external fixators and idealized hybrid fixator. Materials and Methods: A prospective laboratory investigation was used to test the mechanical stiffness between the new proposed hybrid fixator (Figure 1) and the more commonly used hybrid external fixators: AceFischer, DePuyACE, Warsaw, IN; Hoffmann II, Stryker Howmedica Osteonics, Rutherford, NJ; Synthes Hybrid, Synthes USA, Paoli, PA; EBI DynaFix®, EBI, Parsippany, NJ; and a custom built “rigid” frame (Figure 2). The test model was a fiberglass composite tibia (Pacific Research Laboratories, Vashon Island, WA, USA) with a 2 cm proximal metaphyseal gap osteotomy simulating the fracture pattern described by OTA classification 41-A3.3. The “rigid” frame consisted of five 15 cm diameter aluminum rings having 2.0 cm square cross-sections and four stainless steel longitudinal connecting rods 1.25 cm diameter. A standardized pin and wire configuration was created by using the “rigid” frame as a guide for drilling holes in each test tibia for placement of wires and pins. Proximal loading was through a custom load plate mounted on the tibial plateau and distal loading was through a universal joint mounted at the level of the ankle. Direct compression and torsion loads were applied using a biaxial servohydraulic load frame (Model 858 Bionix, MTS, Eden Prairie, MN). Five loading regimes were used; central compression, medial compression, posterior compression, postero-medial compression, and torsion. The compression load was 100 N in each case. The proximal load plate offset the medial and posterior loading by 4 cm resulting in 4 N-m of bending in those loading modes. The postero-medial loading resulted in 5.66 N-m of bending. The torsional loading was 5 N-m. The amount of displacement (mm or deg) of the MTS actuator was recorded for each test. Each of the five fixation types were applied to three separate tibiae. Each tibia construct was loaded and data recorded for three test runs with wires re tensioned between each run. The multiple runs were used to confirm that the testing procedure was consistent. Analysis of Variance (ANOVA) followed by post-hoc t-tests was used to compare the amount of displacement allowed by the four configurations for each loading mode (p<0.05). Separate validation tests were performed on the “rigid” frame to determine its stiffness. A 0.75 cm thick plate was mounted on the top ring of a five ring configuration of the “rigid” frame. The custom load plate was then mounted to the thick plate and loaded as described previously. The load developed for very small motions was recorded and the stiffness of the “rigid” frame was calculated. Results: The new proposed hybrid external fixator was stiffer than all the other fixators tested in all modes of testing (P<0.05), except for torsion. The Hoffman II, DePuyACE, EBI, and Synthes fixators were essentially equivalent in stiffness in all five modes of testing (P>0.05). Discussion: The hybrid fixators, or the fixators that use the thin wire fixation in the periarticular fragment combined with the half-pin fixation in the diaphysis, have made the multiplanar external fixation easier to use and thus growing in popularity (1). However, the configuration of the ideal hybrid has not been elucidated yet. Decreasing the distance of the side bar to the center of the bone effectively shortens the length of the half-pins, which decreases their deflection during bending, and thus increases stiffness (2). We measured the distance between the bone surface and point of fixation of wires and halfpins (table). We think that a better stiffness of new fixator than of others is due to a shorter distance between the bone surface and points of fixation of wires and half-pins. The proposed hybrid fixator corresponds to the contemporary requirements for external fixation: high stiffness, easy to apply, comfortable for the patient (being light and simple), low cost. References: 1. Pugh K.J., Wolinsky P.R., Pienkowski D., Banit D., Dawson J.M. Comparative biomechanics of Hybrid External fixation. J. Orthop. Trauma. 1999; 13(6): 418-425. 2. Tencer A.F, Johnson K.D. Biomechanics in Orthopedic Trauma. J.B.Lippincott Company, Philadelphia. 1994. Distance between the bone surface and point of fixation of wires and half-pins (cm).
منابع مشابه
Unstable proximal extraarticular tibia fractures: a biomechanical evaluation of four methods of fixation.
OBJECTIVE To compare the biomechanical stability of extraarticular proximal tibia fractures reconstructed using a double-plate construct, locking plate system, hybrid external fixator, and single lateral periarticular plate, all from the same manufacturer. DESIGN Standardized proximal tibial fractures (AO classification 41-A3.2 and A3.3) in synthetic tibiae were stabilized using one of the fo...
متن کاملA Biomechanical Comparison between Taylor’s Spatial Frame and Ilizarov External Fixator
ABSTRACT Taylor's spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanical properties of these two external fixators. This study looks into the mechanical characteristics of each system. TSF rings with 6 oblique struts, 4 tube connectors, 4...
متن کاملA biomechanical comparison of micromotion after ankle fusion using 2 fixation techniques: intramedullary arthrodesis nail or Ilizarov external fixator.
BACKGROUND In difficult ankle arthrodesis situations, intramedullary (IM) arthrodesis nails and external fixation are often considered in lieu of standard fusion techniques. The purpose of this study was to compare the amount of micromotion measured across an ankle fusion site stabilized with either an IM nail or with the Ilizarov external fixator. MATERIALS AND METHODS The relative bone mine...
متن کاملManagement of Tibial Metaphyseal Fractures by Hybrid External Fixator
Introduction: The Hybrid External Fixator combines the advantages of the monolateral pin fixators and the circular Ilizarov wire fixators. Principle of early motion has been touted as the functional savior of major intra articular injuries in application of hybrid external fixation. Materials & Methodology: 48 patients were considered for the study with tibial fractures admitted in Mamata Gener...
متن کاملTreatment of Pediatric Open Femoral Fractures with External Fixator Versus Flexible Intramedullary Nails
Background: In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. Methods: In this descriptive analytical study, 27 ...