Captured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty

نویسندگان

  • Mun Chul Kim
  • Shelby Bennett
  • Richard Farb
  • Sydney Croul
  • Seon-Kyu Lee
چکیده

The authors present a case in which macro-embolus from the ruptured atheromatous plaque developed during carotid artery stenting (CAS). A 63-year-old man who had suffered a left middle cerebral artery territory infarction had significant proximal left internal carotid artery stenosis required CAS procedure. Immediate after stent deployment, the patient showed abrupt neurological deterioration with 12 × 3 mm sized macro-embolus which was caught by the embolus protection device (EPD). Retrieval of the macro-embolus was performed safely and the patient recovered to pre-procedure status. Macro-embolus can be resulted during the CAS. The EPD can capture the macro-embolus and safe removal is technically feasible.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of the distal balloon protection technique in the prevention of cerebral embolic events during carotid stent placement.

BACKGROUND AND PURPOSE We sought to quantitatively and qualitatively evaluate the release of atheromatous plaque debris induced by carotid stenting procedures. METHODS Eight patients with severe carotid atheromatous stenoses were treated by stent implantation under distal balloon protection. Blood samplings were obtained after stent deployment in the blood pooled below the inflated protection...

متن کامل

Observation of the embolus protection filter for Carotid Artery Stenting.

BACKGROUND Carotid artery stenting in patients with high surgical risk is considered as an effective alternative to carotid endarterectomy. Because the occurrence of distal embolization with CAS is still a major concern, an embolus protection device is usually used during the procedure. We developed a technique for observation of embolus protection filter and evaluated the debris or thrombus mi...

متن کامل

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Surgical management for retained distal embolic protection device and fractured guidewire after carotid artery stenting

Entrapment and fracture of carotid angioplasty and stenting hardware is a rare complication of percutaneous stenting procedures. We describe a case of a retained distal filter embolic protection device and guidewire in a 57-year-old male in Beijing, China. After unsuccessful attempts at removal via interventional methods, a second stent was deployed to secure the original hardware in situ, and ...

متن کامل

A Case of In-Stent Neoatherosclerosis 10 Years after Carotid Artery Stent Implantation: Observation with Optical Coherence Tomography and Plaque Histological Findings

We report a patient's case of slow progressive in-stent restenosis 10 years after bare-metal stent implantation to his carotid artery. We treated the patient with an additional stent placement under a distal filter protection device. Optical coherence tomographic assessment and plaque histology during the carotid artery stenting (CAS) revealed atheromatous change at in-stent neointima, which co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013