The Mechanical Benefit of Medial Support Screws in Locking Plating of Proximal Humerus Fractures

نویسندگان

  • Wen Zhang
  • Langqing Zeng
  • Yanjie Liu
  • Yao Pan
  • Wei Zhang
  • Changqing Zhang
  • Bingfang Zeng
  • Yunfeng Chen
چکیده

BACKGROUND The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs) in the locking proximal humeral plate for treating proximal humerus fractures. METHODS Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed. RESULTS Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001). When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P ≤ 0.0207). Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture. CONCLUSIONS Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures.

BACKGROUND The objective of this study was to investigate the biomechanical effects of medial fracture gap augmentation in locked plating of an unstable 2-part proximal humeral fracture with calcar screws and insertion of a corticocancellous bone block. Furthermore the mechanical behavior of dynamic locking screws in the non-parallel arrangement of a proximal humeral plate was of interest. ME...

متن کامل

Evaluation of Clinical and Radiological Outcome of Fracture Proximal Humerus by Locking Compression Plate Taking into Consideration of Biomechanics of the Glenohumeral Joint

Proximal humerus fractures account for approximately 4 – 5% of the all fractures [1,2,3]. The incidence of fracture is more common in the elderly because of decreased bone density. But it can occur in younger age group following high velocity trauma [3]. Because of increasing incidence of high velocity trauma, the fracture patterns in proximal humerus are becoming complicated. It has been alway...

متن کامل

Mechanical assessment of local bone quality to predict failure of locked plating in a proximal humerus fracture model.

The importance of osteoporosis in proximal humerus fractures is well recognized. However, the local distribution of bone quality in the humeral head may also have a significant effect because it remains unclear in what quality of bone screws of standard implants purchase. The goal of this study was to investigate whether the failure of proximal humerus locked plating can be predicted by the Den...

متن کامل

Assessment of Screw Length of Proximal Humerus Internal Locking System (PHILOS) Plate for Proximal Humeral Fractures Using Three-Dimensional Computed Tomography Scan

BACKGROUND Screw perforation and varus collapse are common complications of treatment with a PHILOS (proximal humerus internal locking system) plate for proximal humerus fractures, which are associated with improper screw length selection and lack of medial column support. The purposes of this study were: (1) to measure the proper length of periarticular screws of the PHILOS plate in the humera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014