Mechanical interference between a closure device and the rigid stent of mitral bioprosthesis: a mechanism for closure device late dislodgement.
نویسندگان
چکیده
: We report here the mechanical interference between mitral bioprostheses and devices currently adopted for percutaneous paravalvular leak closure as a possible cause for late dislodgement and embolization of successfully implanted and apparently stable closure devices.The images included in this study demonstrate that the topographical relationship of the target leak with the bioprosthetic valve posts may be a major obstacle for device stability after percutaneous paravalvular leak closure procedures.
منابع مشابه
Compressive Behavior of a Glass/Epoxy Composite Laminates with Single Delamination
The buckling and postbuckling behaviors of a composite beam with single delamination are investigated. A three-dimensional finite element model using the commercial code ANSYS is employed for this purpose. The finite elements analyses have been performed using a linear buckling model based on the solution of the eigenvalues problem, and a non-linear one based on an incremental-iterative method....
متن کامل'Fast-implantable' aortic valve implantation and concomitant mitral procedures.
Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mi...
متن کاملThermo-mechanical behavior of shape memory alloy made stent- graft by multi-plane model
Constitutive law for shape-memory alloys subjected to multi-axial loading, which is based on a semi-micromechanical integrated multi-plane model capable of internal mechanism observations, is generally not available in the literature. The presented numerical results show significant variations in the mechanical response along the multi loading axes. These are attributed to changes in the marten...
متن کاملUrgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series
Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...
متن کاملMitral prosthetic valve regurgitation due to stent fracture of a porcine bioprosthesis.
Mitral prosthetic valve regurgitation due to stent fracture with consequent cusp prolapse occurred in two patients with a Wessex porcine bioprosthesis.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cardiovascular medicine
دوره 17 Suppl 2 شماره
صفحات -
تاریخ انتشار 2016