Oblique central refraction in tilted spherocylindrical lenses.

نویسنده

  • Ralf Blendowske
چکیده

Spectacle corrections worn in a frame with a faceform tilt should be used with effective spherocylindrical parameters. For the case of oblique central refraction, Keating presented a procedure to determine these parameters in a third-order approximation. The central equation of his approach, the effective dioptric power matrix, is partly the result of an educated guess. Based on the equations of wavefront tracing, an analytical derivation of his equation, slightly modified however, is given in this paper.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ABCD matrix for reflection and refraction of laser beam at tilted concave and convex elliptic paraboloid interfaces and studying laser beam reflection from a tilted concave parabola of revolution

Studying Gaussian beam is a method to investigate laser beam propagation and ABCD matrix is a fast and simple method to simulate Gaussian beam propagation in different mediums. Of the ABCD matrices studied so far, reflection and refraction matrices at various surfaces have attracted a lot of researches. However in previous work the incident beam and the principle axis of surface are in parallel...

متن کامل

ABCD Matrix for Reflection and Refraction of Laser Beam at Tilted Concave and Convex Elliptic Paraboloid Interfaces and Studying Laser Beam Reflection from a Tilted Concave Parabola of Revolution

ARTICLE HISTORY: Received 04 March 2015 Revised 22 March 2015 Accepted 22 March 2015 Studying Gaussian beam is a method to investigate laser beam propagation and ABCD matrix is a fast and simple method to simulate Gaussian beam propagation in different mediums. Of the ABCD matrices studied so far, reflection and refraction matrices at various surfaces have attracted a lot of researches. However...

متن کامل

Tolerance and Nature of Residual Refraction in Symmetric Power Space as Principal Lens Powers and Meridians Change

Unacceptable principal powers in well-centred lenses may require a toric over-refraction which differs in nature from the one where correct powers have misplaced meridians. This paper calculates residual (over) refractions and their natures. The magnitude of the power of the over-refraction serves as a general, reliable, real scalar criterion for acceptance or tolerance of lenses whose surface ...

متن کامل

Measurement and Topography Guided Treatment of Irregular Astigmatism

Corneal astigmatism occurs when one corneal meridian has a different refractive power from the orthogonal meridian. In regular astigmatism, the two meridians are at 90o from each other, such as a sphere having a cylinder superimposed on its surface. In irregular astigmatism the two meridians are not at 90o from each other or the cornea curvature is not axially symmetric. Irregular astigmatism c...

متن کامل

Sigma models on curved space and bubble refraction in doped antiferromagnets

The dynamics of bubble solitons in two-dimensional isotropic antiferromagnets, inhomogeneously doped so that the exchange integral J becomes position dependent, is studied. In the usual continuum approximation, the system reduces to a nonlinear sigma model on a spacetime whose geometry depends on J(x). It is shown, both within the geodesic approximation, and by appealing to field theoretic cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 79 1  شماره 

صفحات  -

تاریخ انتشار 2002