Laboratory evaluation of the Anderson Technical semiautomated susceptibility testing system.
نویسندگان
چکیده
Anderson Technical, Inc. has developed rapid, semiautomated equipment for antimicrobial susceptibility testing. A total of 310 fresh clinical bacterial isolates (226 gram-negative and 75 gram-positive) were tested with the Anderson Technical system and compared with those of Micro-Media Systems, Inc. For the gram-positive organisms, 74.3% of the test pairs had identical minimum inhibitory concentration values, whereas 99.1 and 0.9% of the test pairs had minimal inhibitory concentration values differing by less than or equal to 1 and greater than 1 dilution level, respectively. Identical minimum inhibitory concentration values were obtained for 67.2% of the gram-negative test pairs, whereas 97.6 and 2.4% differed by less than or equal to 1 and greater than 1 dilution level, respectively. For all organisms tested, 98.0% differed by less than or equal to 1 dilution level. The Anderson Technical equipment proved to be a rapid and flexible system for microdilution testing.
منابع مشابه
Laboratory Diagnosis of Nosocomial Bacterial Infections Using Standard Methods
Background and objective: Implementation of standard methods for accurate detection of bacteria, correct antibiotic susceptibility testing and effective treatment of bacterial infections play important roles in development of public health and prevention of drug resistance. This study aimed to detect bacteria using standard methods and compare the results with the results obtained in teaching h...
متن کاملEvaluation of Carbapenemase and Integron Resistance Genes in Pseudomonas Aeruginosa Isolated from Clinical Samples and Determination of Antibiotic Resistance Pattern by Laboratory Method
Introduction: Pseudomonas aeruginosa is one of the most important bacteria causing nosocomial infections, especially in immunocompromised patients. Many antibiotics such as aminoglycosides, quinolones, and beta-lactams are used to treat infections caused by this bacterium. But the emergence of hospital resistance and outbreaks of resistance strains have been widely reported. The aim of this stu...
متن کاملStrategic Planning to Establish Quality System in Medical Laboratory
Abstract Background and Objective: Every organization requires ongoing evaluation of existing conditions. The purpose of this study is to assess and analyze the standards and criteria that each Laboratory system is required to observe and upgrade them, to determine the gap between the ideal and the current status and finally to present the strategy and executive plan in order to...
متن کاملMolecular Identification and Conventional Susceptibility Testing of Iranian Clinical Mycobacterium fortuitum Isolates
Objective(s) Rapidly growing mycobacteria (RGM) are capable of producing diseases in humans. Since mycobacteria vary in their susceptibility, precise identification is critical for adoption of correct drug therapy. The main aim of this study was molecular identification and evaluation of antimicrobial susceptibility pattern of Iranian clinically isolated Myocbacterium fortuitum. Materials and...
متن کاملFluconazole Susceptibility Profile of Candida isolates Recovered from Patients Specimens Admitted to Yazd Central Laboratory
The increasing incidence of candidiasis and antifungal resistance as well as the introducing of new antifungal has recently encouraged performing of fungal susceptibility testing. The aim of this study was to evaluate the susceptibility profile of Candida species isolated from patients admitted to Yazd central laboratory to fluconazole. We used the broth microdilution method to evaluate the sus...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Antimicrobial agents and chemotherapy
دوره 20 6 شماره
صفحات -
تاریخ انتشار 1981