Structural control benchmark problem: Phase II—Nonlinear smart base-isolated building subjected to near-fault earthquakes
نویسندگان
چکیده
Many branches of engineering, mathematics, and sciences, have relied on benchmark problems as a standard means to compare different solution techniques. Since 1996, the ASCE Structural Control and Monitoring Committee and Task Group on Benchmark Problems, the U.S. Panel on structural control, and IASCM have developed a series of benchmark control problems that offer a set of carefully modeled real-world structures in which different control strategies can be implemented, evaluated, and compared using a common set of performance indices. First-, secondand third-generation benchmark problems focusing on the response control of seismic and wind-excited buildings, and seismically excited long-span cable-stayed bridges have been developed and evaluated. The U.S. Panel on structural control and monitoring (currently chaired by Professor Satish Nagarajaiah, Rice University, Houston, TX), IASCM, and the ASCE structural control and monitoring committee have developed a new benchmark study to compare control strategies designed for a base-isolated building subjected to strong near-fault pulse-like ground motions. The special issue on phase I smart base-isolated building benchmark problem with a linear isolation system was successfully completed and published. This special issue focuses on the phase II smart base-isolated building benchmark problem with nonlinear isolation systems—friction or elastomeric system. Copyrightr 2008 John Wiley & Sons, Ltd.
منابع مشابه
Semiactive control strategy for a phase II smart base isolated benchmark building
This paper presents a semiactive control strategy for the seismic protection of the phase II smart base isolated benchmark building subjected to near-fault earthquakes. Magnetorheological (MR) fluid dampers controlled by an optimal direct output feedback control algorithm with a voltage generator are used as semiactive control devices. The benchmark building is an eight-story base isolated buil...
متن کاملStudy and Comparison of Seismic Behaviour of Isolator-Damper Hybrid Control System with Conventional Structural Systems
In this paper, in addition to introduce a hybrid structural system contained local isolators and dampers, its behavior and functional capabilities were studied on a conventional structure. For this purpose, an RC frame building with six-story was designed based on valid codes and then, in four cases based on the number of spans, it was split into two separate adjacent frames. Base isolation was...
متن کاملEvaluation of Nonlinear Response of Structures to Near-Fault Ground Motions and the Comparison of Results with Near-Fault Simulated Records
Near-fault ground motions have caused very much damage in the vicinity of seismic sources during recent earthquakes. It is well known that under specific circumstances, intensive ground shakings near fault ruptures may be characterized by short-duration impulsive motions. This pulse-type motion is generally particular to the forward direction, where the fault rupture propagates towards the site...
متن کاملSmart base-isolated benchmark building. Part II: phase I sample controllers for linear isolation systems
Sample controllers for a three-dimensional smart base-isolated building benchmark problem with linear and frictional isolation system are presented in this paper. A Kalman filter is used to estimate the states based on absolute acceleration measurements. Input filters are used to better inform the controller of the spectral content of the earthquake excitations. A reduced order control-oriented...
متن کاملBenchmark structural control problem for a seismically excited highway bridge-Part III: Phase II Sample controller for the fully base-isolated case
This paper presents the fully base-isolated highway bridge benchmark problem. The highway bridge benchmark problem consists of two phases: (1) Phase I—the bridge deck being base isolated only at the abutments and the center bent being integral with the pier (without isolation), and (2) Phase II—the bridge deck being fully base isolated at both the bent/pier and abutment locations. In both phase...
متن کامل