Analytical Challenges and Strategies in FE-EPMA
نویسندگان
چکیده
Unquestionably, since their introduction one decade ago, field emission (FE) electron microprobes have pushed the boundaries of electron probe microanalysis (EPMA) by offering new possibilities to characterize smaller features. As with conventional microprobes, the proper selection of the analytical conditions (beam energy, beam current, acquisition time, x-ray line) is essential to obtain an accurate and precise quantification. With FE microprobes, the new challenge is to optimize these parameters to obtain the best spatial resolution. Our previous work [1] has shown that, as each analytical condition has a different influence on the accuracy, precision and spatial resolution, a compromise must be found depending on the characterization goals. In continuation, this work aims at evaluating the influence of instrumental parameters, such as the focusing capability, beam stability and stage reproducibility, on high resolution acquisitions, and proposing strategies to perform reliable and automated measurements.
منابع مشابه
Grazing-exit X-ray spectrometry for surface and thin-film analyses.
Electron-probe x-ray micro analysis (EPMA) and particle-induced x-ray emission analysis (PIXE) were performed under grazing-exit conditions. To control the exit angle (take-off angle), a new sample holder having a stepping motor was developed for grazing-exit EPMA. A carefully polished surface of a stainless-steal sample was measured. The surface of stainless steel is normally covered with a th...
متن کاملStrategies for Low Accelerating Voltage X-ray Microanalysis of Sub-Micrometer Features with the FE-EPMA
X-ray microanalyses of sub-micrometer features require that a lower accelerating voltage be used. This reduction in the accelerating voltage reduces the penetrating distance of the beam electrons and thereby reduces the analytical volume. Two general strategies have been proposed for achieving the smallest analytical volume. The first approach involves significantly reducing the accelerating vo...
متن کاملRevisiting the electron microprobe method of spinel-olivine-orthopyroxene oxybarometry applied to spinel peridotites
Natural peridotite samples containing olivine, orthopyroxene, and spinel can be used to assess the oxygen fugacity ( fO2) of the upper mantle. The calculation requires accurate and precise quantification of spinel Fe3+/SFe ratios. Wood and Virgo (1989) presented a correction procedure for electron microprobe (EPMA) measurements of spinel Fe3+/SFe ratios that relies on a reported correlation bet...
متن کاملChallenges and Strategies Regarding Spatial Development of the Annexed Villages of Gorgan
With accelerated urban growth during past decades in the country,one could well observed the annexation phenomena. This unplanned and spontaneous annexation paved the way for the development of sputter settlements in the margin and edges of the cities. This study aims to investigate the challenges and barriers that these new borne communities are of Ouzineh and Anjirab encountered with. It plan...
متن کاملQuantitative Energy-dispersive Electron Probe X-ray Microanalysis of Individual Particles
An electron probe X-ray microanalysis (EPMA) technique using an energy-dispersive X-ray detector with an ultra-thin window, designated low-Z particle EPMA, has been developed. The low-Z particle EPMA allows the quantitative determination of concentrations of low-Z elements such as C, N, and O, as well as higher-Z elements that can be analyzed by conventional energydispersive EPMA. The quantitat...
متن کامل