Tapping mode microwave impedance microscopy.

نویسندگان

  • K Lai
  • W Kundhikanjana
  • H Peng
  • Y Cui
  • M A Kelly
  • Z X Shen
چکیده

We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately simulated by the finite-element analysis and the result agrees quantitatively to the experimental data on a series of thin-film dielectric samples. The tapping mode microwave imaging is also superior to the contact mode in that the thermal drift in a long time scale is totally eliminated and an absolute measurement on the dielectric properties is possible. We demonstrated tapping images on working nanodevices, and the data are consistent with the transport results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application Note #145 Nanoscale Mapping of Permittivity and Conductivity with Scanning Microwave Impedance Microscopy

is an AFM-based technique for materials and device characterization. The reflected microwave signal from the tip-sample interface holds information of the electrodynamic properties of the sample surface underneath the tip apex. Detecting and processing of the reflectance in real time allows sMIM to directly access the permittivity and conductivity of materials. When an AFM-type sMIM probe is sc...

متن کامل

Topography imaging with a heated atomic force microscope cantilever in tapping mode.

This article describes tapping mode atomic force microscopy (AFM) using a heated AFM cantilever. The electrical and thermal responses of the cantilever were investigated while the cantilever oscillated in free space or was in intermittent contact with a surface. The cantilever oscillates at its mechanical resonant frequency, 70.36 kHz, which is much faster than its thermal time constant of 300 ...

متن کامل

Tapping mode atomic force microscopy in liquid

We show that standard silicon nitride cantilevers can be used for tapping mode atomic force microscopy (AFM) in air, provided that the energy of the oscillating cantilever is sufficiently high to overcome the adhesion of the water layer. The same cantilevers are successfully used for tapping mode AFhif in liquid. Acoustic modes in the liquid excite the canti1eve.r. On soft samples, e.g., biolog...

متن کامل

Vertical dimension of hydrated biological samples in tapping mode scanning force microscopy.

The vertical dimensions of the well-characterized test samples tobacco mosaic virus, T4 bacteriophage polyhead, purple membrane, and hexagonally packed intermediate (HPI) layer were investigated by tapping mode scanning force microscopy (SFM) in solution. Purple membrane and HPI layer were imaged in both contact mode and tapping mode SFM for direct comparison. All vertical dimensions match the ...

متن کامل

Phase imaging and stiffness in tapping-mode atomic force microscopy

The dependence of phase angles in tapping-mode atomic force microscopy on the magnitude of tip-sample repulsive interactions was investigated, and phase images of several hard and soft samples were recorded as a function of the free amplitude Ao and the set-point tapping amplitude Asp. The phase angle of probe oscillation increases with decreasing the set-point amplitude ratio Asp/Ao. Phase ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 80 4  شماره 

صفحات  -

تاریخ انتشار 2009