Numerical extraction of Cole-Cole impedance parameters from step response
نویسندگان
چکیده
In this paper we propose a numerical method to extract the four parameters (Ro, R∞, C, and α) that characterize a single-dispersion Cole-Cole impedance model from its step response, based on modelling the step response using fractional calculus, without requiring direct measurement of the real and imaginary impedance parts. MATLAB simulations using Cole-Cole impedances of fruit tissues with α < 1, PSPICE simulations and experimental results using a Cole-Cole model with α = 1 are given to verify the method. Extracted impedance parameters show less than 0.1% relative error in simulation and less than 10% error in experimental results for the extracted impedance parameters.
منابع مشابه
Cole Parameter Estimation from the Modulus of the Electrical Bioimpeadance for Assessment of Body Composition. A Full Spectroscopy Approach
Activities around applications of Electrical Bioimpedance Spectroscopy (EBIS) have proliferated in the past decade significantly. Most of these activities have been focused in the analysis of the EBIS measurements, which eventually might enable novel applications. In Body Composition Assessment (BCA), the most common analysis approach currently used in EBIS is based on the Cole function, which ...
متن کاملModeling of Bioimpedance for Human Skin Based on Fractional Distributed- Order Modified Cole Model
Electrical impedance measurement data and fractional calculus have been utilized for modeling bioimpedance properties of human skin. We introduced and proposed revisited Cole model using modified distributedorder operator based on the Caputo-Weyl fractional derivatives. Our proposed model presents essentially modified single-dispersion Cole model, since it introduces a new parameters k and σ in...
متن کاملIn Vivo Blood Characterization From Bioimpedance Spectroscopy of Blood Pooling
Characterization of blood impedance properties is important to estimate clinical diagnostic indices such as haematocrit, glucose level and hydration. Current in vivo bioimpedance spectroscopy methods are performed on a body appendage and thus represent a combined measurement of all tissues in the measurement field, rather than the blood individually. This paper describes a novel in vivo measure...
متن کاملEvaluation of algorithms for calculating bioimpedance phase angle values from measured whole-body impedance modulus.
This paper addresses the problem of calculating the bioimpedance phase angle from measurements of impedance modulus. A complete impedance measurement was performed on altogether 20 healthy persons using a Solatron 1260/1294 system. The obtained impedance modulus (absolute impedance value) values were used to calculate the Cole parameters and from them the phase angles. In addition, the phase an...
متن کاملStructural, Electrical, and impedance spectroscopy studies of Barium substituted nano calcium ferrites synthesized by solution combustion method.
Barium substituted nanocrystalline ferrites with chemical composition BaxCa1-xFe2O4 (x =0.0 to 0.25) BCAF were prepared by solution combustion method. The phase formation of mixed spinal structured ferrites was confirmed by PXRD analysis. The average crystallite size was calculated using Debye-Scherrer formula and it was found to be in the range of 27-44 nm. Surface morphology was analyzed by S...
متن کامل