Application of adsorptive voltammetry for the detection of sub-nano molar cyclizine in biological fluids and tablets using fast Fourier transform continuous cyclic voltammetry in a flowing system.

نویسندگان

  • Parviz Norouzi
  • Rassoul Dinarvand
  • Mohammad Reza Ganjali
  • Aliakbar Moosavi-Movahedi
  • Aliakbar Saboury
  • Atefeh Tamaddon
چکیده

An easy and fast Fourier transform continuous cyclic voltammetric technique (FFTCV) for monitoring of ultra trace amounts of cyclizine in a flow-injection system has been introduced in this work. The potential waveform, which was applied continuously on an Au disk microelectrode (12.5 microm in radius) consisted of the potential steps for cleaning, accumulation and potential ramp. The proposed detection method has some advantages, the greatest of which are as follows: first, it is no longer necessary to remove oxygen from the analyte solution and second, this is a very fast and appropriate technique for determination of the drug compound in a wide variety of chromatographic analysis methods. The detection limit for cyclizine was 1.8 ng ml(-1). The relative standard deviation (RSD) of the proposed technique at 5.0 x 10(-7) was 2.0 for 10 runs. The influences of pH of eluent, accumulation potential, sweep rate, and accumulation time on the determination of the cyclizine were considered. The proposed method was applied to the determination of cyclizine in a pharmaceutical preparation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Riboflavin by Nanocomposite Modified Carbon Paste Electrode in Biological Fluids Using Fast Fourier Transform Square Wave Voltammetry

Herein, fast Fourier transformation square-wave voltammetry (FFT-SWV) as a novel electrochemical determination technique was used to investigate the electrochemical behavior and determination of Riboflavin at the surface of a nanocomposite modified carbon paste electrode. The carbon paste electrode was modified by nanocomposite containing Samarium oxide (Sm2O3)/reduced gra...

متن کامل

DNA Biosensor for Determination of 5-Fluorouracil based on Gold Electrode Modified with Au and Polyaniline Nanoparticles and FFT Square Wave Voltammetry

In the present study, a new biosensor for 5-Fluorouracil was described using modified goldelectrode and Fast Fourier transform square wave voltammetry (FFT SWV). Calf thymus DNAimmobilization was on a gold electrode decorated with polyaniline and gold nanoparticles. Theelectrochemical characteristics of the electrodes were investigated by cyclic voltammetry, andelectroch...

متن کامل

Application of FFT Cyclic Voltammetry for Monitoring Removal of Mercury Ions from Aqueous Environment using New Adsorbent based Modified Mesoporous Silica (SBA–15)

As the electrochemical method, the Fast Fourier Transform (FFT) Stripping Cyclic Voltammetry detection method was designed for measurement and monitoring of adsorbed mercury ions by new modified adsorbent based on mesoporous silica as a new adsorbent. In this respect, SBA-15 as mesoporous silica and 1, 3, 5 Trithiane as effective modifier ligand were chosen, and the modification process was car...

متن کامل

Cyclic voltammetry of bulk and nano manganese sulfate with Doxorubicin using glassy Carbon electrode

The cyclic voltammetry of both bulk manganese sulfate (BMS) and nano manganese sulfate (NMS) were studied using 0.1M KCl supporting electrolyte and glassy carbon working electrode. The redox behavior for both bulk (BMS) and MnSO4 (NMS) sulfate was studied voltammetrically in presence and absence of Doxorubicin (DR) using three electrodes system, silver- silver chloride (Ag/AgCl), pla...

متن کامل

Cyclic voltammetry of bulk and nano manganese sulfate with Doxorubicin using glassy Carbon electrode

The cyclic voltammetry of both bulk manganese sulfate (BMS) and nano manganese sulfate (NMS) were studied using 0.1M KCl supporting electrolyte and glassy carbon working electrode. The redox behavior for both bulk (BMS) and MnSO4 (NMS) sulfate was studied voltammetrically in presence and absence of Doxorubicin (DR) using three electrodes system, silver- silver chloride (Ag/AgCl), pla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 25 4  شماره 

صفحات  -

تاریخ انتشار 2009