Accurate non-invasive determination of pKa of surface functionalised ion exchange monoliths using capacitively coupled contactless conductivity detection.

نویسندگان

  • Eoin Gillespie
  • Damian Connolly
  • Pavel N Nesterenko
  • Brett Paull
چکیده

The use of on-column capacitively coupled contactless conductivity detection for the accurate non-invasive visualisation of the pH dependence of covalently bound boronic acid groups within a monolithic polymeric capillary column is demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of contactless conductivity detection for non-invasive characterisation of monolithic stationary-phase coatings for application in capillary ion chromatography.

A capacitively-coupled contactless conductivity detector (C4D) has been utilised as an on-capillary detector within a capillary ion chromatograph, incorporating a reversed-phase monolithic silica capillary column semi-permanently modified with a suitable ionic surfactant. The monolithic capillary column (150 x 0.1 mm i.d.) was modified using sodium dioctyl sulfosuccinate (DOSS), an anionic surf...

متن کامل

Comparison of Potassium and Sodium Content in Diet and Non-Diet Soft Drinks by Using Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection

Capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection (C4D) was used for determination of sodium and potassium concentrations in diet and non-diet soft drinks. Higher sodium concentrations were found in the diet samples due to the utilization of sodium salts of cyclamate and saccharine as sweeteners. The CE-C4D method can be used by food industries and heal...

متن کامل

Study of the determination of inorganic arsenic species by CE with capacitively coupled contactless conductivity detection.

The determination of arsenic(III) and arsenic(V), as inorganic arsenite and arsenate, was investigated by CE with capacitively coupled contactless conductivity detection (CE-C(4)D). It was found necessary to determine the two inorganic arsenic species separately employing two different electrolyte systems. Electrolyte solutions consisting of 50 mM CAPS/2 mM L-arginine (Arg) (pH 9.0) and of 45 m...

متن کامل

Determination of anions using monolithic capillary column ion chromatography with end-to-end differential contactless conductometric detectors under resonance approach.

An end-to-end differential measurement approach with capacitively coupled contactless conductivity detection (C(4)D) was applied to anion-exchange monolithic capillary column ion chromatography. The column was prepared by thermally initiated radical polymerization of poly(glycidyl methacrylate) in a fused-silica capillary of 320 μm i.d. and modified by quaternary ammonium latex surface coating....

متن کامل

Determination of haloacetic acids in water using solid-phase extraction/microchip capillary electrophoresis with capacitively coupled contactless conductivity detection.

Haloacetic acids (HAAs) were determined by a fast and simple analysis method based on microchip electrophoresis and capacitively coupled contactless conductivity detection (C(4)D). Two chlorinated acetic acids, dichloroacetic acid (DCAA) and TCA were detected in swimming pool water. Different BGEs were tested, and sodium carbonate was selected as BGE for the separation and detection in the repo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 133 7  شماره 

صفحات  -

تاریخ انتشار 2008