Evaluation of the comparability and repeatability of four wavefront aberrometers.

نویسندگان

  • Nienke Visser
  • Tos T J M Berendschot
  • Frenne Verbakel
  • Annelie N Tan
  • John de Brabander
  • Rudy M M A Nuijts
چکیده

PURPOSE To compare total ocular aberrations and corneal aberrations identified with four different aberrometers and to determine the repeatability and interobserver variability. METHODS In this prospective comparative study, 23 healthy subjects underwent bilateral examination with four aberrometers: the Irx3 (Hartmann-Shack; Imagine Eyes, Orsay, France), Keratron (Hartmann-Shack; Optikon, Rome Italy), iTrace (ray-tracing; Tracey Technologies, Houston, TX), and OPD-Scan (Automated Retinoscopy; Nidek, Gamagori, Japan). Six images per eye were obtained. Second-, third- and fourth-order spherical aberrations were exported for 5.0-mm pupils. RESULTS Significant differences in measurements were found for several total ocular aberrations (defocus [2,0], astigmatism [2,2], trefoil [3,-3], trefoil [3,3], and spherical aberration [4,0]) and corneal aberrations (defocus [2,0] and astigmatism [2,2]). The Irx3 showed the highest repeatability in measuring total ocular aberrations, followed by the Keratron, OPD-Scan, and iTrace. The repeatability of the corneal aberration measurements was highest for the iTrace, followed by the Keratron and OPD-Scan. The OPD-Scan showed a lower interobserver variability, compared with the Irx3, Keratron, and iTrace. CONCLUSIONS Total ocular and corneal aberrations are not comparable when measured with different aberrometers. Hartmann-Shack aberrometers showed the best repeatability for total ocular aberrations and iTrace for corneal aberrations. It would be worthwhile in the future to evaluate aberrometers in patients with more aberrant eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Making sense out of wavefront sensing.

a T p HE PRESENCE OF OPTICAL ABERRATIONS THAT BLUR retinal images were the subject of popular lectures by Helmholtz in the 1860s, and led him to state: Now, it is not too much to say that if an optician wanted o sell me an instrument which had all these defects, I hould think myself justified in blaming his carelessness in he strongest terms and giving him back his instrument.”1 ecently, the av...

متن کامل

Precision and agreement of higher order aberrations measured with ray tracing and Hartmann-Shack aberrometers

BACKGROUND To assess the precision and agreement of measurements of higher order aberrations (HOAs) obtained with a ray tracing aberrometer (iTrace) and a Hartmann-Shack aberrometer (Topcon KR-1 W). METHODS Prospective evaluation of the diagnostic test. Data from the right eyes of 92 normal subjects obtained using the two devices were included in this study. Two observers performed 3 consecut...

متن کامل

Analysis of Four Aberrometers for Evaluating Lower and Higher Order Aberrations

PURPOSE To compare the measurements of lower and higher order aberrations (HOA) of 4 commonly used aberrometers. SETTING Massachusetts Eye & Ear Infirmary, Boston, USA. DESIGN Prospective, cross-sectional study, in a controlled, single-blinded fashion. METHODS Multiple readings were obtained in 42 eyes of 21 healthy volunteers, at a single visit, with each of the following aberrometers: A...

متن کامل

Comparability and repeatability of different methods of corneal astigmatism assessment

Purpose To assess the comparability and repeatability of keratometric and astigmatism values measured by four techniques: Orbscan IIz® (Bausch and Lomb), Lenstar LS 900® (Haag-Streit), Cassini® (i-Optics), and Total Cassini (anterior + posterior surface), in healthy volunteers. Patients and methods Fifteen healthy volunteers (30 eyes) were assessed by the four techniques. In each eye, three c...

متن کامل

Repeatability of corneal first-surface wavefront aberrations measured with Pentacam corneal topography.

PURPOSE To assess the repeatability of corneal wavefront aberrations derived from Pentacam (Oculus) corneal topography. SETTING Flinders Eye Centre, Flinders Medical Centre, Bedford Park, South Australia, Australia. METHODS Forty-five normal participants and 10 participants with keratoconus were tested. Intraobserver and interobserver repeatability was determined using 4 observers within an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 2011