Safe patient transfer system with monitoring of location and vital signs.
نویسندگان
چکیده
In recent years, ubiquitous computing technologies have been applied in the field of medicine. Especially radio frequency identification (RFID) and small sensor networks could provide information about medical practices and patient status in order to prevent malpractices and improve the quality of medical care. As an example of this application, we developed a new system, named "a smart stretcher," which continuously monitors the patient's vital signs and detects apnea during transfer within a hospital. This system consists of a small air-mat type pressure sensor measuring both heart rate and respiration rate and a wireless network transmitting these vital data as well as patient ID to an alerting system to notify hospital staff of patient emergencies. Results of experiments in a clinical setting indicated that the system was reliable in continuous respiration monitoring and detection of apnea during patient transfer on the stretcher; however, detection of heartbeat rate was practically difficult because of the motion noises. Moreover patient ID and location were also correctly detected in real time. These results suggested the feasibility of our system for real clinical use.
منابع مشابه
Requirements for Designing a Wearable Smart Blanket System for Monitoring Patients in Ambulance
Introduction: Nowadays, smart systems and advanced tools such as wearable systems have grown significantly in order to monitor patients and keep their condition under control. The aim of this study was to determine the requirements for designing a wearable smart blanket system (WSBS) to monitor patients in ambulance instantaneously. Method: After reviewing the characteristics of wearable system...
متن کاملRequirements for Designing a Wearable Smart Blanket System for Monitoring Patients in Ambulance
Introduction: Nowadays, smart systems and advanced tools such as wearable systems have grown significantly in order to monitor patients and keep their condition under control. The aim of this study was to determine the requirements for designing a wearable smart blanket system (WSBS) to monitor patients in ambulance instantaneously. Method: After reviewing the characteristics of wearable system...
متن کاملسوراخ شدن رحم خانم باردار حین کولهسیستکتومی لاپاروسکوپیک: گزارش موردی
Background: Laparoscopy is an acceptable procedure for cholecystitis in pregnancy. Laparoscopic complications during pregnancy can be unique. Uterine perforation is a rare complication during laparoscopy of pregnant women. Acquaintance with this complication can help surgeons and gynecologist to manage these patients properly. We will report a case of uterine perforation during laparoscopy. Ca...
متن کاملطراحی سیستم تصمیمیار پایش علائم حیاتی بیماران بستری در بخش مراقبتهای ویژه قلبی
Introduction: Big volume of patient’s medical data is one of the medical error reasons in coronary care unit (CCU). The purpose of this study was the designing a system that can monitored the patient’s vital sign continuously and when there are abnormal, producing alarms and proposed appropriate medical interventions according to the patient’s conditions in CCU. Metho...
متن کاملThe Ability of GSM Mobile Phone Users in Detecting Exposure to Electromagnetic Fields and the Bioeffects of These Fields on their Vital Signs
Background & Aims: Since previous studies on complications resulting from exposure to electromagnetic fields emitted by mobile phones are based only on self- reported symptoms, this study was performed to find the capability of users in recognition of real/ sham microwave exposure and probable alterations of vital signs after microwave exposure. Methods: In a two- step screening, from 700 stude...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of medical and dental sciences
دوره 55 1 شماره
صفحات -
تاریخ انتشار 2008