Blockage of a mechanical aortic valve leaflet with Bioglue: a case report.

نویسنده

  • Tone Gabrijelcic
چکیده

Mechanical aortic valve dysfunction is a very rare event and is usually due to thrombosis, pannus overgrowth, or both. BioGlue as a cause for such a complication has been reported only occasionally. We describe a case of a 63-year-old woman who underwent operation for symptomatic tight aortic stenosis. After implantation of an aortic valve (AGN-751, size 19; St. Jude Medical, St. Paul, MN, USA) because of a transverse tear of the aortic wall above the annulus occurring during the suturing of the aortotomy, a triangular Vascutek Dacron patch (Vascutek/Terumo, Inchinnan, Scotland, UK) was included. To secure hemostasis, BioGlue (CryoLife, Kennesaw, GA, USA) was applied. A transthoracic echocardiography (TTE) examination performed after signs of ischemia appeared in the electrocardiogram on postoperative day 5 revealed an aortic transvalvular gradient of 74/38 mm Hg and a functional valve area of 1.0 cm2. No coronary lesions were revealed in a coronarography evaluation, but cinefluoroscopy (CF) examination revealed immobility of 1 valve leaflet. The reoperation revealed a thick, rough layer of the glue on the inner side of the patch. This glue had run down to the valve, blocking a mechanical leaflet. Cleaning the valve was not possible, and the valve had to be changed. The subsequent postoperative course was uneventful. The transvalvular gradient was 39/20 mm Hg, and the functional valve area was 1.2 cm2. We believe that the use of BioGlue and other surgical sealants is justified to secure complex suture lines and for maintaining hemostasis in cardiac surgery, but some precautionary rules must be respected. Authors have indicated that the glue enters through the needle holes in such cases, but our findings suggest it can also pass to the Dacron patch itself. CF is superior to TTE and transesophageal echocardiography for analyzing movement of the mechanical valve leaflet, and cardiac catheterization is rarely needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

Ostial left coronary stenosis following aortic root reconstruction with BioGlue.

Haemorrhage is a major concern during repair of acute aortic dissection. In such circumstances, glue is often used for tissue reconstruction and also to fortify vascular anastomoses. In this report, we describe a rare case of ostial left main coronary artery stenosis potentially related to previous use of BioGlue.

متن کامل

Successful Repair of Type a Aortic Dissection in a Term Pregnancy: A Case Report

Stanford type A acute aortic dissection (AAD) is a very rare complication, with potentially lethal consequences in pregnancy. In fact, pregnancy has been regularly associated with the possibility of aortic. dissection in almost half of young women. Herein, we present the case of a 38-year-old woman in her 37th week of pregnancy. The patient’s medical history was indicative of G4L2Ab1(4 gestaiti...

متن کامل

Rheumatic Aortic Valve Disease with Mitral Stenosis—A Case Report

Congenitally malformed aortic valves are more susceptible to valve injury due to rheumatic fever, mechanical stress of altered flow patterns, atherosclerotic risk factors and degenerative changes. Rheumatic involvement usually occurs in childhood and it is progressive leading to diffuse thickening and fibrosis at leaflet edges and thus differentiated from other patterns of valve damage. Backgro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The heart surgery forum

دوره 15 6  شماره 

صفحات  -

تاریخ انتشار 2012